![Rohde & Schwarz CMU-K20 Operating Manual Download Page 307](http://html.mh-extra.com/html/rohde-and-schwarz/cmu-k20/cmu-k20_operating-manual_1477804307.webp)
CMU-K20/K21/K22/K23/K24
Connection Control (Non Signalling only)
1115.6088.12 6.3
E-12
[SENSe:]RFANalyzer:CHANnel <Number>
RF Channel
<Number>
Description of parameters
Def. value
Def. unit
FW vers.
0.2 MHz to 2700 MHz
(see also data sheet)
Input frequency
455 (GSM400)
837 (GSM850)
903 (GSM900)
1750 (GSM1800)
1880 (GSM1900)
MHz
MHz
MHz
MHz
MHz
V2.00
Description of command
This command defines the frequency of the RF signal analyzed. As an alternative to frequencies, the corre-
sponding GSM channels (with the character string CH annexed to the channel number) can be entered (259CH
to 293 CH and 306 to 340 for GSM400, 128CH to 251CH for GSM850, 0CH to 124CH or 955CH to 1023CH for
GSM900, 512CH to 885CH for GSM1800, 512CH to 810CH for GSM1900, see GSM channel tables in chapter
4). The assignment of channel numbers and frequencies meets the GSM specification for the uplink (signal direc-
tion from mobile to CMU). The query always returns frequencies.
[SENSe:]RFANalyzer:FREQuency:OFFSet
<FreqOffset>
Frequency Offset
<FreqOffset>
Description of parameters
Def. value
Def. unit
FW vers.
–100 kHz to +100 kHz
Offset for channel frequency 0
kHz
V1.20
Description of command
This command defines an offset for the channel frequency set with the command
[SENSe:]RFANalyzer:CHANnel <Number>
.
The offset frequency must be in multiples of 1 Hz.
[SENSe:]RFANalyzer:TSEQuence
<TrainingSequence>
Training Sequence
<TrainingSequence>
Description of parameters
Def. value
Def. unit
FW vers.
OFF |
GSM0 to GSM7 |
DUMMy |
ANY
No training sequence detected
GSM-specific training sequence
GSM dummy burst
Arbitrary training sequence allowed
OFF –
V1.15
Description of command
This command determines the training sequence of the signal analyzed. If no training sequence is specified
(OFF),
the CMU measures all signals. In the setting
ANY,
it uses any training sequence for synchronization.
CONFigure:RFANalyzer:TPCL
<PCL>
TPCL
<PCL>
Description of parameters
Def. value
Def. unit
FW vers.
0 to 31
Template PCL
15
–
V2.10
Description of command
This command defines the template PCL which is used for dynamic limit line correction in the
POWer
measure-
ment.
[SENSe:]RFANalyzer:MODulation
<Mod_Scheme>
Modulation
<Mod_Scheme>
Description of parameters
Def. value
Def. unit
FW vers.
GMSK | EPSK
Modulation scheme GMSK or EPSK
GMSK
–
V2.15
Description of command
This command selects one of the supported modulation schemes.
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...