![Rohde & Schwarz CMU-K20 Operating Manual Download Page 109](http://html.mh-extra.com/html/rohde-and-schwarz/cmu-k20/cmu-k20_operating-manual_1477804109.webp)
CMU-K20/K21/K22/K23/K24
Non Signalling: Power Measurements
1115.6088.12 4.31
E-11
Average power
denotes the RF carrier power averaged over the useful part of the
measured burst (application
P/t Normal 8PSK)
or of the measured timeslot
(application
P/t Multislot
with 8PSK modulation, see
Slot Count
softkey on p.
4.57
).
Owing to the characteristics of 8PSK modulation, the amplitude of the RF signal varies with
the transmitted data. As a consequence, only the long term average of the power when taken
over the useful part of the burst for random data represents a correct measure for the output
power of the mobile phone. This long time average (rather than the average power of the
current burst) is also the correct reference power (0-dB line) for the
P/t Norm. 8PSK
measurement.
The
Average
setting ensures that a correct reference power is used, however, averaging
results in a longer measurement time. In the
Data Compensated
mode, a known data
sequence is used to correct the measured average power of the current burst and estimate
the correct reference power. Delays due to averaging are avoided.
Remote control
CONFigure:POWer[:NORMal]:EPSK:CONTrol:RPMode
CURRent | AVERage | DCOMpens
P/t Multislot –
Timing Offset
The
Timing Offset
shifts the burst by the entered number of symbol periods, e.g. to
compensate for a known, constant timing error of the MS. The burst is shifted
relative to the time axis and the tolerance template for the multislot burst analysis.
Therefore, the value of
Timing Offset
affects the result of the tolerance check.
Remote control
CONFigure:POWer:MSLot:TOFFset
P/t Multislot –
Modulation View
The
Modulation View
section defines the expected modulation scheme in all four
timeslots that can be measured and adjusts the power/time template. To obtain a
valid measurement result, the actual modulation in all measured slots must be
compatible with the
Modulation View
settings. Otherwise, the CMU displays a
warning:
"Signal does not match configuration!"
The following settings are provided for all slots:
GPSK
GMSK modulation expected; the GMSK power/time template is used
8PSK
8PSK modulation expected; the 8PSK power/time template is used
ANY
Arbitrary modulation scheme; the CMU determines the modulation of
the measured burst and uses the appropriate template. Valid results
are obtained with both GMSK and 8PSK modulation.
OFF
No signal expected: timeslot must be inactive to obtain a valid result
The
Modulation View
settings are ignored for all slots that are not measured.
Remote control
CONFigure:POWer:MSLot:MVIew
P/t Multislot –
Slot Count
The
Slot Count
defines an integer number of timeslots to be measured in the P/t
Multislot application. The actual time range measured is larger than the integer
number of slots because it comprises an additional display margin; for details see
remote control command description.
Remote control
CONFigure:POWer:MSLot:SCOunt
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...