Measurement Groups (Non Signalling only) CMU-K20/K21/K22/K23/K24
1115.6088.12 6.14
E-12
CONFigure:POWer[:NORMal]:EPSK:CONTrol:RPMode
<Mode>
Ref. Power Mode
<Mode>
Description of parameters
Def. value
Def. unit
FW vers.
CURRent |
AVERage |
DCOMpens
Ref. Power calculated from current burst
Ref. Power calculated from average curve
Data compensated/corrected reference power
CURR –
V2.15
Description of command
This command determines how the reference power (0-dB line in the
P/t Norm. 8PSK
test diagram) for 8PSK-
modulated signals is calculated.
CONFigure:POWer[:NORMal][:GMSK]:CONTrol:DEFault <Enable>
Default Settings
CONFigure:POWer[:NORMal]:EPSK:CONTrol:DEFault <Enable>
<Enable>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
The parameters are set to their default values
Some or all parameters differ from the default values
ON
– V2.00
Description of command
If used as a setting command with the parameter
ON
this command sets all parameters of the subsystem to their
default values (the setting
OFF
causes an error message).
If used as a query the command returns whether all parameters are set to their default values
(ON)
or not
(OFF)
.
Subsystem POWer:LIMit:LINE
The subsystem
POWer:LIMit:LINE
defines the limit lines, i.e. the tolerance values for the power meas-
urement. The subsystem corresponds to the tab
Limit Lines
in the popup menu
Power Configuration.
CONFigure:POWer[:NORMal][:GMSK]:LIMit:LINE:UPPer<nr>[:STATic]:ENABle
<Enable>
CONFigure:POWer[:NORMal]:EPSK:LIMit:LINE:UPPer<nr>[:STATic]:ENABle
<Enable>
CONFigure:POWer[:NORMal][:GMSK]:LIMit:LINE:UPPer<nr>[:STATic]
CONFigure:POWer[:NORMal]:EPSK:LIMit:LINE:UPPer<nr>[:STATic]
Upper Limit Line
Parameters for query:
<StartTime>, <EndTime>, <StartRelLevel>, <EndRelLevel>,
<StartAbsLevel>,
<EndAbsLevel>,
<StartVisibility>, <EndVisibility>
for setting:
<StartTime>, <EndTime>, <StartRelLevel>, <EndRelLevel>,
<StartAbsLevel>, <EndAbsLevel>, <Visibility>
Parameters
Value range
Description of parameters
Def. values
<Enable>
<StartTime>,
<EndTime>,
<StartRelLevel>,
<EndRelLevel>,
<StartAbsLevel>,
<EndAbsLevel>,
<Visibility>
<StartVisib>
<EndVisib>
ON | OFF
–10 bit to +156 ¾ bit | OFF
–10 bit to +156 ¾ bit | OFF,
–100 dB to 20 dB | OFF,
–100 dB to 20 dB | OFF,
–90 dBm to 50.0 dBm OFF,
–90 dBm to 50.0 dBm | OFF,
ON | OFF
Area on/off
Start point of time
End point of time
Start point of level (relative)
End point of level (relative)
Start point of level (absolute)
End point of level (absolute)
Range of limit lines on/off
see below
Description of command
FW vers.
These commands activate and define upper limit lines for normal bursts. The limit lines are defined
area by area; the suffix <nr> numbers the various areas in the burst diagram (see chapter 4).
V1.15
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...