Common: POWer:MSLot
CMU-K20/21/22/23/24
1115.6088.12 6.56
E-12
CONFigure:POWer:MSLot:CONTrol:DEFault
<Enable>
Default Settings
<Enable>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
The parameters are set to their default values
Some or all parameters are not set to default
ON
– V3.05
Description of command
If used as a setting command with the parameter
ON
this command sets all parameters of the subsystem to their
default values (the setting
OFF
causes an error message).
If used as a query the command returns whether all parameters are set to their default values
(ON)
or not
(OFF)
.
Test Configuration
The commands of the following subsystems configure the
P/t Multislot
measurement. They correspond
to some of the softkey/hotkey combinations in the graphical measurement menu and to some of the
settings in the
Power Configuration
popup menu that are related to the
P/t Multislot
measurement.
CONFigure:POWer:MSLot:MVIew
<Mod_-1>,<Mod_0>, <Mod_1>, <Mod_2>
Modulation View
<Mod_1>, ... , <Mod_2>
Description of parameters
Def. value
Def. unit
FW vers.
GMSK |
EPSK |
ANY |
OFF
GMSK modulation required
8PSK modulation required
GMSK or 8PSK modulation
Inactive timeslot (power off) required
ANY –
V3.05
Description of command
This command defines the modulation schemes and power/time templates for the Meas. Timeslot –1, Meas.
Timeslot and the two following timeslots. Values for timeslots that are currently switched off (see command
CONFigure:POWer:MSLot:SCOunt
) are not taken into consideration.
CONFigure:POWer:MSLot:SCOunt
<Slots>
Slot Count
<Slots>
Description of parameters
Def. value
Def. unit
FW vers.
1 |
2 |
3 |
4
Meas. timeslot (MTS)
MTS – 1, MTS
MTS – 1, MTS, MTS + 1
MTS – 1, MTS, MTS + 1, MTS + 2
2 – V3.05
Description of command
This command defines the number of timeslots measured and determines the length of the measurement arrays
(see
READ:ARRay:POWer:MSLot
...
commands). The measured timeslot is defined via
CONFigure:RFANalyzer:MCONtrol:TSOFfset
(Non Signalling) or
CONFigure:MSSignal:MCONtrol:MESLot
(Signalling).
CONFigure:POWer:MSLot:TOFFset
<Offset>
Timing Offset
<Offset>
Description of parameters
Def. value
Def. unit
FW vers.
–4.00 to +4.00
Number of bits (in ¼ symbol steps)
0
symb.
V3.05
Description of command
This command defines an offset time by which the burst is shifted relative to the time axis and the tolerance
template. The values entered are rounded to ¼ symbol steps.
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...