![Rohde & Schwarz CMU-K20 Operating Manual Download Page 370](http://html.mh-extra.com/html/rohde-and-schwarz/cmu-k20/cmu-k20_operating-manual_1477804370.webp)
Common: MODulation[:PERRor]
CMU-K20/21/22/23/24
1115.6088.12 6.66
E-12
CONFigure:MODulation[:PERRor][:GMSK]:CONTrol:REPetition
Test Cycles
<
Repetition
>
,<StopCond>,<Stepmode>
<Repetition>
Description of parameters
Def. value
Def. unit
CONTinuous |
SINGleshot |
1 to 10000
Continuous measurement (until
STOP
or
ABORT)
Single shot measurement (until
Status = RDY
)
Multiple measurement
(
counting
, until
Status = STEP | RDY)
SING –
<StopCond>
Description of parameters
Def. value
Def. unit
SONerror |
NONE
Stop measurement in case of error
(stop on error)
Continue measurement even in case of error
NONE –
<Stepmode>
Description of parameters
Def. value
Def. unit
FW vers.
STEP |
NONE
Interrupt measurement after each statistics cycle
Continue measurement according to its rep. mode
NONE –
V1.15
Description of command
This command determines the number of statistics cycles, the stop condition and the stepping mode for the
measurement.
Note:
In the case of READ commands (
READ:
...), the <Repetition> parameter has no effect; the
measurement is always stopped after a single shot.
CONFigure:MODulation[:PERRor][:GMSK]:CONTrol:DEFault
<Enable>
Default
Settings
<Enable>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
The parameters are set to their default values
Some or all parameters differ from the default values
ON
– V1.15
Description of command
If used as a setting command with the parameter
ON
this command sets all parameters of the subsystem to their
default values (the setting
OFF
causes an error message).
If used as a query the command returns whether all parameters are set to their default values
(ON)
or not
(OFF)
.
Tolerance values – Subsystem MODulation[:PERRor][:GMSK]:LIMit
The subsystem
MODulation[:PERRor][:GMSK]:LIMit
defines tolerance values for the modulation
measurement. The subsystem corresponds to the tab
Limits
in the popup menu
Modulation
Configuration.
CONFigure:MODulation[:PERRor][:GMSK]:LIMit[:CURRent]
Upper Modulation Errors
<PhaseErrorPeak>,<PhaseErrorRMS>,<FrequencyError>
Parameter
Description of parameters
Def. value
Def. unit
FW vers.
0.0 deg to +50.0 deg
0.0 deg to +50.0 deg
0.0 Hz to +999 Hz
PhaseErrorPeak
PhaseErrorRMS
FrequencyError
+20.0
+5.0
+90
deg
deg
Hz
V1.15
Description of command
This command defines limits for the peak and RMS phase error as well as for the frequency error in the current
or maximum trace. The default frequency error is 49 Hz for GSM400, 90 Hz for GSM850 and GSM900, 180 Hz
for GSM1800, 190 Hz for GSM1900. Besides, the ranges and default values for the upper and lower
PhaseErrorPeak
and
FrequencyError
limits have equal magnitude but different sign.
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...