CMU-K20/21/22/23/24 Signalling: Receiver Quality
1115.6088.12 6.167
E-12
CONFigure:RXQuality:BAVerage:LIMit:USFBler <USF_BLER>
USF Block Error Rate
<USF_BLER>
Description of parameters
Def. value
Def. unit
FW vers.
0 % to 100 %
Upper limit for USF block error rate
10.0
%
V3.05
Description of command
This command defines an upper limit for the USF BLER.
CONFigure:RXQuality:BAVerage:LIMit:DEFault <Enable>
Default Settings
<Enable>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
The parameters are set to default values
Some or all parameters differ from the default value
ON
– V2.00
Description of command
As a
setting command
with the setting
ON
this command sets all parameters of the subsystem to default values
(the setting
OFF
causes an error message).
As a query, this command reads out whether all parameters are set to default values
(ON)
or not
(OFF)
.
Measured Values – Subsystem RXQuality:BAVerage
The subsystem
RXQuality:BAVerage
contains the commands for measurement and output of the bit
error rate and its comparison with the tolerance values. The subsystem corresponds to the
measurement menus
Receiver Quality
for the continuous measurement.
Scalar Results
FETCh[:SCALar]:RXQuality:BAVerage?
Read out results (unsynchronized)
SAMPle[:SCALar]:RXQuality:BAVerage?
Read out results (synchronized)
Returned values for RFER
Value range
Def. value
Def. unit
ProgressTime,
ClassIIBits,
ClassIbBits,
FER,
CRCErrors,
Status
0.0 to 100.0 %
0.000 to 100.000 %
0.000 to 100.000 %
0.000 to 100.000 %
0 to 500
INV | PASS | FAIL | TLOW | IMP
NAN
NAN
NAN
NAN
NAN
INV
%
%
%
%
–
–
Returned values for BER
Value range
Def. value
Def. unit
ProgressTime,
ClassIIBits,
ClassIbBits,
CRCErrors,
Status
0.0 to 100.0 %
0.000 to 100.000 %
0.000 to 100.000 %
0 to 500
INV | PASS | FAIL | TLOW | IMP
NAN
NAN
NAN
NAN
INV
%
%
%
–
–
Returned values for BBB
Value range
Def. value
Def. unit
ProgressTime,
ClassIIBits,
CRCErrors,
Status
0.0% to 100.0%
0.000% to 100.000%
0 to 500
INV | PASS | FAIL | TLOW | IMP
NAN
NAN
NAN
INV
%
%
–
–
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...