CMU-K20/21/22/23/24 Common: MODulation[:OVERview]
1115.6088.12 6.83
E-12
CONFigure:MODulation:OEMP:EPSK:LIMit:P95Th
95
th
Percentile
<EVM95%>, <MError95%>, <PError95%>
Parameter
Description of parameters
Def. value
Def. unit
FW vers.
0% to 50.0%,
0% to 50.0%,
0° to +180°
95
th
percentile EVM
95
th
percentile modulation error
95
th
percentile phase error
+5.0
+5.0
+5.0
%
%
deg
V2.15
Description of command
This command defines upper limits for the 95
th
percentile of the three quantities
error vector magnitude
,
modula-
tion error
, and
phase error
. The 95
th
percentile is the limit below which 95% of the measured errors are located.
CONFigure:MODulation:OEMP:EPSK:LIMit:DEFault
<Enable>
Default
Settings
<Enable>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
The parameters are set to their default values
Some or all parameters differ from the default values
ON
– V2.15
Description of command
If used as a setting command with the parameter
ON
this command sets all parameters of the subsystem to their
default values (the setting
OFF
causes an error message).
If used as a query the command returns whether all parameters are set to their default values
(ON)
or not
(OFF)
.
Measured Values – Subsystem MODulation:OVERview:EPSK
The subsystem
MODulation:OVERview:EPSK
measures and returns the modulation parameters and
compares them with the tolerance values. The subsystem corresponds to the various output elements
in the measurement menu
MODulation,
application
Overview 8PSK.
READ[:SCALar]:MODulation:OVERview:EPSK?
Scalar Results:
Start single shot measurement and return results
FETCh[:SCALar]:MODulation:OVERview:EPSK?
Read out meas. results (unsynchronized)
SAMPle[:SCALar]:MODulation:OVERview:EPSK?
Read out measurement results (synchronized)
Returned values
Value range
Def. value
Def. unit
FW vers.
95thPercentileEVM,
95thPercentileMagErr,
95thPercentilePhErr,
EVMPeak (x3),
EVMRMS (x3),
MagnErrorPeak (x3),
MagnErrorRMS (x3),
PhErrorPeak(x3),
PhErrorRMS (x3),
OriginOffset (x3),
FrequencyError (x3),
AvgBurstPowerCurr,
BurstsOutOfTol
0.0 % to 100.0 %
0.0 % to 100.0 %
–100.0 deg to +100.0 deg
0.0 % to 100.0 %
0.0 % to 100.0 %
0.0 % to 100.0 %
0.0 % to 100.0 %
–100.0 deg to +100.0 deg
–100.0 deg to +100.0 deg
–100.0 dB to +100.0 dB
–1000.0 Hz to +1000.0 Hz
–137 dBm to +53 dBm
0.0 % to 100.0 %
NAN
NAN
NAN
NAN
NAN
NAN
NAN
NAN
NAN
NAN
NAN
NAN
NAN
%
%
deg
%
%
%
%
deg
deg
dB
Hz
dBm
%
V2.15
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...