![Rohde & Schwarz CMU-K20 Operating Manual Download Page 507](http://html.mh-extra.com/html/rohde-and-schwarz/cmu-k20/cmu-k20_operating-manual_1477804507.webp)
CMU-K20/21/22/23/24 Connection
Control (Signalling only)
1115.6088.12 6.203
E-12
CONFigure:NETWork[:CSWitched]:TIMeout:RLINk[:MOBile]
<Time>
Radiolink Timeout Mobile
<Time>
Description of parameters
Def. value
Def. unit
FW vers.
4 to 64
Number of missing SACCH blocks (the step size is 4)
24
–
V1.15
Description of command
Sig. State
This command defines the maximum number of SACCH blocks which may be missing before a
mobile phone
considers the radio link to be interrupted
(radio link timeout)
≠
CEST,
Q: all
CONFigure:NETWork[:CSWitched]:TIMeout:RLINk:TESTset
<Time>
Radiolink Timeout Testset
<Time>
Description of parameters
Def. value
Def. unit
FW vers.
4 to 64 |
OFF
Number of missing SACCH blocks (the step size is 1)
Monitoring of radio link is switched off (ie there is no Sync.
Lost in the case of missing SACCH blocks)
24 – V1.15
Description of command
Sig. State
This command determines the maximum number of SACCH blocks which may be missing before the
CMU considers the radio link to be interrupted
(radio link timeout for test set)
.
≠
CEST,
Q: all
CONFigure:NETWork[:CSWitched]:TIMeout:MTC
<Time>
MTC Timeout
<Time>
Description of parameters
Def. value
Def. unit
FW vers.
0 s to 60 s
OFF
Time limit for call to mobile
No time limit (unlimited ringing)
10 s
V1.15
Description of command
Sig. State
This command determines the maximum dialing time until the mobile accepts the call
(mobile
terminated call timeout)
; after this time, the attempted call setup is aborted.
In the setting OFF, ringing is possible for an unlimited period of time.
≠
CEST,
Q: all
Connector Subsystems (External Attenuation at the Connectors)
The commands in this section configure the input and output connectors. The commands correspond
to the tab
RF
in the popup menu
Connect. Control
.
INPut[:STATe]
<State>
RF Input
<State>
Description of parameters
Def. value
Def. unit
FW vers.
RF1
RF2
RF4
Connector RF1 used as input
Connector RF2 used as input
Connector RF4 IN used as input
RF2 – V1.15
Description of command
Sig. State
This command determines the connector to be used for RF input signals. The bidirectional
connectors RF1 and RF2 can be used both as input and output connectors in the same measurement
(see
OUTPut[:STATe]
).
Only one input and one output may be active at the same time, a new RF input setting overwrites the
previous one.
all
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...