Non Signalling: Spectrum Measurements
CMU-K20/K21/K22/K23/K24
1115.6088.12 4.58
E-11
Switching
GMSK
The
Switching GMSK
hotkey selects the spectrum due to switching for GMSK
modulated signals to be displayed. In this mode, the power at the nominal
frequency and the relative power at up to 4 neighboring frequencies is displayed in
a single graph, see p.
4.60
ff.
Remote control
No explicit switchover command. All spectrum due to modulation measurements
are identified by the 2
nd
to 4
th
level keywords
...SPECtrum:SWITching[:GMSK]
Switching
8PSK
The
Switching 8PSK
hotkey selects the spectrum due to switching for 8PSK
modulated signals to be displayed. In this mode, the power at the nominal
frequency and the relative power at up to 4 neighboring frequencies is displayed in
a single graph, see p.
4.60
ff.
Remote control
No explicit switchover command. All spectrum due to modulation measurements
are identified by the 2
nd
to 4
th
level keywords
...SPECtrum:SWITching:EPSK
Measurement Results
The
Spectrum
measurement menu and the results depend on the type of spectrum (application)
selected. The scaling of the x-axis is equal for the two spectra. However, the spectrum due to
modulation is expressed in relative units (dBc), the spectrum due to switching in absolute units (dBm).
a) Spectrum due to Modulation
In the
Spectrum due to Modulation
measurement, the average burst power at a series of fixed
frequency points around the selected RF frequency is displayed. The results and the corresponding
settings are indicated in two parameter lines, the test diagram (bar graph), and an info box.
Parameter lines
Bar graph and
info box
Fig. 4-25 Display of results (spectrum due to modulation)
Parameter lines
The first parameter line contains the following settings:
Max. Level
Maximum input level set as in the
Analyzer
tab of the
Connection Control
menu
(see section
Table-Oriented
Version
on p.
4.73
ff.)
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...