Non Signalling: Modulation Measurements
CMU-K20/K21/K22/K23/K24
1115.6088.12 4.40
E-11
Measurement
configuration
Pressing the
Ext. Phase Err. GMSK
softkey twice opens the popup menu
Modulation Configuration
(see page
4.50
ff.). Besides, the hotkeys
Repetition, Stop
Condition,
and
Statistic Count
defining the scope of the measurement and the
Trig.
Slot Offset
hotkey are associated to the
Ext. Phase Err. GMSK
softkey. The
function of these hotkeys is explained in the
Power
menu section
(see section
P/t
Normal GMSK
on page
4.11
f.); they are identical with the parameters set in the
Control t
ab of the
Modulation Configuration
menu
(see page
4.50
ff.).
The
Ext. Phase Err. GMSK
hotkey bar contains two additional hotkeys:
Disp. Mode
The
Disp. Mode
hotkey selects one of the following display modes:
Current
Measured value for current burst
Minimum/Maximum
Extreme value of a number of bursts
Average
Average value of a number of bursts
See section
Measurement Control (Modulation Configuration – Control)
on
page
4.50
ff.
Remote control
No display mode set explicitly, the three measurement curves are accessible via
FETCh:ARRay:MODulation:XPERror[:GMSK][:BURSt]
[:CURRent]?
FETCh:ARRay:MODulation:XPERror[:GMSK][:BURSt]:MMAX?
FETCh:ARRay:MODulation:XPERror[:GMSK][:BURSt]
:AVERage?
etc.
Decode
The
Decode
hotkey defines whether or not guard or tail bits are decoded.
See section
Measurement Control (Modulation Configuration – Control)
on
page
4.50
ff.
Remote control
CONFigure:MODulation:XPERror[:GMSK]:TIME:DECode
STANdard | GTBits
Application
The
Application
softkey selects the modulation scheme. Only one application of the
Modulation
menu is related to GMSK modulated signals. The 8PSK applications
are described in section
Test Settings
on p.
4.45
f.
Phase Err.
GMSK
The
Phase Error GMSK
hotkey selects the extended phase error measurement on
GMSK modulated signals.
Remote control
The
Phase Error GMSK
application is selected by the keywords
XPERror[:GMSK]
in the 3
rd
and 4
th
level of the
MODulation
commands, e.g.
CONFigure:MODulation:XPERror[:GMSK]...
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...