6-75
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
F9-02
EF0 Detection
0, 1
---
0
Basic or Advanced
Explanation of Settings
Setting
Description
0
Always detects communications external faults
1
Detects communications external faults during operation.
Parameter
number
Display name
Setting
range
Units
Default
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
F9-03
EF0 Fault Action
0 to 3
---
1
Basic or Advanced
Explanation of Settings
Setting
Description
Inverter’s status
Fault output
0
Deceleration 2: Decelerates to a stop
with C1-02 set.
Fault
ON
1
Coast to a stop.
Fault
ON
2
Emergency stop time: Decelerates to a
stop according to the C1-09 setting.
Fault
ON
3
Continuous operation. (See note.)
Alarm
OFF
D
Torque Limit/Torque Reference Operation Selection via Communications
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
F9-05
Torq Ref/Lmt Sel
0, 1
---
1
Not applicable.
Basic or
Ad-
vanced
Explanation of Settings
Setting
Description
0
The communications torque reference/torque limit reference is disabled.
1
The communications torque reference/torque limit reference is enabled.
Note Set the parameter to 1 because the CompoBus/D Communications Card does not support torque
references or torque limit references.
D
Selection of Operation for Communications Failures
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
F9-06
BUS Fault Sel
0 to 3
---
1
Basic or Advanced
Set the parameter according to the application.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...