5-28
H
Setting a User-defined V/f Pattern (Setting “F”)
Parameters E1-04 through E1-10 can be set by the user when E1-03 has been set to “F.” These param-
eters are read-only when E1-03 isn’t set to “F.” Parameters E1-04 through E1-10 cannot be changed
during operation.
When making the V/f characteristics a straight line, set the same value in E1-07 (middle output frequen-
cy) and E1-09 (minimum output frequency). In this case, parameter E1-08 (middle output voltage) will
be ignored.
Parameter
Display name
Setting
Units
Default
Valid access levels
*1
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
E1-04
Max Frequency
40.0 to 400.0
Hz
60.0
Q
Q
Q
Q
E1-05
Max Voltage
0.0 to 255.0
*2
VAC
200.0
*2
Q
Q
Q
Q
E1-06
Base Frequency
0.0 to 400.0
Hz
60.0
Q
Q
Q
Q
E1-07
Mid Frequency A
0.0 to 400.0
Hz
3.0
Q
Q
A
---
E1-08
Mid Voltage A
0.0 to 255.0
*2
VAC
15.0
*2,3
Q
Q
A
---
E1-09
Min Frequency
0.0 to 400.0
Hz
1.5
Q
Q
Q
A
E1-10
Min Voltage
0.0 to 255.0
*2
VAC
9.0
*2,3
Q
Q
A
---
Note 1. Q: Quick-start, Basic, or Advanced
A:
Advanced only
---: Not applicable.
Note 2. These voltages are for the 200-V class; Double the voltage for 400-V class Inverters.
Note 3. The default setting depends on the Inverter’s capacity. The default settings shown in the table
are for 200-V class, 0.4 to 1.5 kW Inverters. Refer to the graphs for “Setting: 1” on pages 5-26
and 5-27 for the default settings in 2.2 to 45 kW and 55 to 300 kW Inverters.
Note 4. The default settings for E1-07 through E1-10 depend on the control mode. The default set-
tings shown in the table are for V/f control.
Note 5. The four frequency settings must satisfy the following formula:
E1-04 (F
MAX
)
≥
E1-06 (F
A
) > E1-07 (F
B
)
≥
E1-09 (F
MIN
)
For flux vector control, make the settings as follows:
E1-04 (F
MAX
)
≥
E1-06 (F
A
) > E1-09 (F
MIN
)
User-defined V/f Pattern
Output voltage (V)
Frequency (Hz)
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...