6-37
Group
Control mode
Function
Group
Flux
Vector
Open-loop
Vector
V/f
w/PG
V/f
Function
Options
F1
PG Option Setup
Parameter settings for a PG Speed Control Card
---
OK
---
OK
O
o s
F2
AI-14 Setup
Parameter settings for an Analog Command Card
OK
OK
OK
OK
F3
DI-08, 16 Setup
Parameter settings for a Digital Command Card
OK
OK
OK
OK
F4
AO-08, 12 Setup
Parameter settings for an Analog Monitor Card
OK
OK
OK
OK
F5
Not used
(Do not change these settings.)
---
---
---
---
F6
Not used
( o o c a ge
ese se
gs )
F7
PO-36F Setup
Parameter settings for a Pulse Monitor Card
OK
OK
OK
OK
F8
SI-F/G Setup
Parameter settings for a SYSMAC BUS Interface
Card.
OK
OK
OK
OK
F9
CP-916 Setup
Parameter settings for a CompoBus/D Communica-
tions Card.
OK
OK
OK
OK
Terminal
H1
Digital Inputs
Function selection for multi-function inputs
OK
OK
OK
OK
e
a
H2
Digital Outputs
Function selection for multi-function outputs
OK
OK
OK
OK
H3
Analog Inputs
Adjustment/function selection for external analog
inputs
OK
OK
OK
OK
H4
Analog Outputs
Adjustment/function selection for multi-function ana-
log outputs
OK
OK
OK
OK
H5
Not used
(Do not change these settings.)
---
---
---
---
Protection
L1
Motor Overload
Sets electrical/thermal functions that protect the mo-
tor.
OK
OK
OK
OK
L2
PwrLoss Ridethru
Selects the power-loss processing method.
OK
OK
OK
OK
L3
Stall Prevention
Accel/Decel stall prevention settings and selection
OK
OK
OK
OK
L4
Ref Detection
Frequency detection settings and selection
OK
OK
OK
OK
L5
Fault Restart
Fault restart function settings
OK
OK
OK
OK
L6
Torque Detection
Sets overtorque detection functions 1 and 2
OK
OK
OK
OK
L7
Torque Limit
Not used. (Can’t be set.)
---
---
OK
OK
L8
Hdwe Protection
Hardware overheating and phase loss protection
settings
OK
OK
OK
OK
Operator
o1
Monitor Select
Selects the Operator’s display and setting methods.
OK
OK
OK
OK
O e a o
o2
Key Selections
Operator’s key function selection and other parame-
ters
OK
OK
OK
OK
6-4-2 Energy-saving Control Function
The energy-saving control function is enabled when the energy-saving command (setting 63) has been
set in a multi-function input (H1-01 through H1-06). Inputting the energy-saving command while there is
a light load causes the Inverter’s output voltage to be reduced and saves energy. Turn OFF the energy-
saving command when a normal load is added.
Parameter b8-01 determines the Inverter’s output voltage when the energy-saving command is input.
Set this value as a percentage of the V/f pattern’s voltage. Parameter L2-04 (the voltage recovery time)
determines the rate at which the output voltage is changed when the energy-saving command is turned
ON or OFF.
Parameter b8-02 determines the lower limit frequency for the energy-saving function. The energy-sav-
ing command is enabled only when the frequency reference is above this lower limit and the motor
speed is within the “speed agree” range.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...