6-96
•
Torque Reference (Setting: 13)
Torque Compensation Bias (Setting: 14)
100%
–10 V
10 V
–100%
0
•
Forward Torque Limit (Setting: 10)
Reverse Torque Limit (Setting: 11)
Regenerative Torque Limit (Setting: 12)
100%
–10 V
10 V
0
•
Forward/Reverse Torque (Speed) Limit (Setting: 15)
100%
10 V
–100%
0
H
Multi-function Analog Output Settings (H4)
D
Function Selection Parameters
Parameter
Display name
Setting
1 2
Units
Default
Valid access levels
number
p y
g
range
1,2
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
H4-01
Terminal 21 Sel
1 to 38
---
2
Basic or Advanced
H4-04
Terminal 23 Sel
1 to 38
---
3
Basic or Advanced
Note These parameters cannot be changed during operation.