7-30
Para
meter
No.
Page
Control mode
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Name
Para
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
control
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Display
name
F1-02
PG discon-
nection
stopping
method
(PGO)
Sets the PG disconnection
stopping method.
0:
Ramp to stop (Deceleration
stop using deceleration time
1, C1-02.)
1:
Coast to stop
2:
Fast stop (Emergency stop
using the fast stop time
0 to 3
1
NO
X
B
X
B
5-31,
5-47
PG Fdbk
Loss Sel
using the fast-stop time,
C1-09.)
3:
Continue operation (This
setting can’t be made with
flux vector control.)
F1-03
PG
overspeed
stopping
method
Sets the stopping method when
an overspeed (OS) fault occurs.
0:
Ramp to stop (Deceleration
stop using deceleration time
1, C1-02.)
1:
Coast to stop
2:
Fast stop (Emergency stop
0 to 3
1
NO
X
B
X
B
5-31,
5-48
PG
OverSpeed
Sel
2:
Fast stop (Emergency stop
using the fast-stop time,
C1-09.)
3:
Continue operation (This
setting can’t be made with
flux vector control.)
F1-04
PG speed
deviation
stopping
method
Sets the stopping method when
a speed deviation (DEV) fault
occurs.
0:
Ramp to stop (Deceleration
stop using deceleration time
1, C1-02.)
1:
Coast to stop
0 to 3
3
NO
X
B
X
B
5-32,
5-48
PG
Deviation
Sel
1:
Coast to sto
2:
Fast stop (Emergency stop
using the fast-stop time,
C1-09.)
3:
Continue operation (DEV is
displayed and control
continued.)
F1-05
PG rotation
setting
0:
Phase A leads with forward
command. (Phase B leads
with reverse command )
0, 1
0
NO
X
B
X
B
5-30
PG
Rotation
Sel
with reverse command.)
1:
Phase B leads with forward
command. (Phase A leads
with reverse command.)
F1-06
PG output
ratio
Sets the division ratio for the
PG speed control card pulse
output.
Division ratio = (1+ n) /m (n=0,1
m=1 to 32)
F1 - 06 =
m
1 to
132
1
NO
X
B
X
B
5-30
PG Output
Ratio
Note: This parameter is only ef-
fective when a 3G3FV-
PPGB2 is used.
The possible division ratio
settings are:
1/32
)
F1-06
)
1.
m
n
Parameter Lists
Chapter 7
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...