Parameter Access Level
The SYSDRIVE 3G3FV’s has three access levels which divide the various parameters based on their
usage, as shown below. The access level restricts which parameters can be set or displayed.
Level
Function
Quick-start
Allows setting/reading of parameters required for test runs. (factory-set)
Basic
Allows setting/reading of general-purpose parameters.
Advanced
Allows setting/reading of all parameters.
Set the access level in initialize mode with parameter A1-01.
H
Changing the Access Level from Quick-start to Basic
Key sequence
Display
Explanation
** Main Menu **
Operation
Displays operation mode.
** Main Menu **
Initialize
Displays initialize mode.
Select Language
English
Puts the Unit in initialize mode.
Access Level
Quick Start
Switches to the access level parameter.
A1-01= 2 ***
Quick Start
Displays the access level parameter setting.
A1-01= 3
Basic Level
Changes the access level setting to “BASIC.”
Entry Accepted
Writes the new parameter setting.
Access Level
Basic Level
Returns to the access level parameter display.
Preparing for Operation
Chapter 3
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...