2-26
Voltage class
Wire
thickness
(mm
2
)
Terminal
screw
Terminal
Model
400-V Class
3G3FV-B4450
L1, L2, L3, (–), (+)1, (+)2, (+)3, T1, T2, T3
M8
50
14
r, s
M4
0.5 to 5.5
3G3FV-B4550
L1, L2, L3, (–), (+)3, T1, T2, T3
M10
100
M8
22
r, s200, s400
M4
0.5 to 5.5
3G3FV-B4750-E
L1, L2, L3, (–), (+)3, T1, T2, T3
M10
60 x 2P
M8
22
r, s200, s400
M4
0.5 to 5.5
3G3FV-B411K-E
L1, L2, L3, (–), (+)3, T1, T2, T3
M10
60 x 2P
M8
30
r, s200, s400
M4
0.5 to 5.5
3G3FV-B416K-E
L1, L2, L3, (–), (+)3, T1, T2, T3
M12
100 x 2P
M8
50
r, s200, s400
M4
0.5 to 5.5
3G3FV-B418K-E
L1, L2, L3, (–), (+)1, (+)3, T1, T2, T3
M16
325 x 2P
M8
50
r, s200, s400
M4
0.5 to 5.5
3G3FV-B422K-E
L1, L2, L3, (–), (+)1, (+)3, T1, T2, T3
M16
325 x 2P
M8
60
r, s200, s400
M4
0.5 to 5.5
3G3FV-B430K-E
L1, L2, L3, (–), (+)1, (+)3, T1, T2, T3
M16
325 x 2P
M8
60
r, s200, s400
M4
0.5 to 5.5
Note The wire thickness is set for copper wires at 75
°
C.
Installation
Chapter 2
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...