Modes
This section describes the 3G3FV’s various parameter setting and monitoring modes.
S
Inverter Modes
•
The SYSDRIVE 3G3FV Inverter’s parameters and monitoring functions have been organized in
groups, so it is easier to make settings and read data. These function groups are known as modes.
•
The 3G3FV is equipped with 5 modes, as shown in the following table.
Mode
Primary function(s)
Operation mode
The Inverter can be run in this mode.
Use this mode when monitoring values such as frequency references or output
current, displaying fault information, or displaying the fault history.
Initialize mode
Use this mode when selecting the language displayed on the Digital Operator,
selecting the access level for setting/reading parameters, selecting the control mode,
or initializing the parameters.
Program mode
Use this mode when setting/reading the parameters required for operation. The
program-mode functions are subdivided into the following groups:
Application:
Operation mode selection, DC control, speed search, etc.
Tuning:
Acceleration/deceleration times, S-curve characteristics, carrier
frequencies, etc.
Reference:
Settings related to frequency control
Motor:
V/f characteristics and motor parameters
Option:
Settings for Optional Cards
Terminal:
Settings for sequential I/O and analog I/O
Protection:
Settings for the motor and inverter protection functions
Operator:
Selects the Digital Operator’s display and key functions
Auto-tuning
mode
(Usable only with the vector control mode)
Use this mode when running a motor with unknown motor parameters in the vector
control mode. The motor parameters are calculated and set automatically.
Modified
constants mode
Use this mode to set/read parameters that have been changed from their factory-set
values.
S
Switching Modes
•
Once the Unit has been put into operation mode by pressing the Menu Key, the Increment and Decre-
ment Keys can be pressed to switch to other modes.
•
Press the Enter Key to set/read the parameters in each mode.
Preparing for Operation
Chapter 3
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...