3-8
H
Setting the Parameter in the Basic Access Level
The function level will be displayed when the Enter Key is pressed at the program mode display.
Key sequence
Display
Explanation
** Main Menu **
Operation
Displays operation mode.
2 times
** Main Menu **
Programming
Displays program mode.
Function b1
Sequence
Puts the Unit in program mode.
Displays the b1 Sequence function selection.
Function b2
DC Braking
Displays the b2 DC Braking function selection.
Function C1
Accel/Decel
Displays the C1 Accel/Decel function selection.
Accel Time 1
c1-01= 10.0 Sec
Displays C1-01 Acceleration time 1.
Accel Time 1
0010.0 Sec
Selects the parameter so that the leading 0 flashes.
(The digit that can be changed flashes.)
2 times
Accel Time 1
0010.0 Sec
Moves the cursor so that the “1” digit flashes.
Accel Time 1
0020.0 Sec
Changes the 1 to a 2.
Entry Accepted
Writes the new setting.
---
Accel Time 1
c1-01= 20.0 Sec
Returns to the C1-01 Acceleration time 1 display.
Function C1
Accel/Decel
Returns to the program mode display.
Preparing for Operation
Chapter 3
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...