3-14
Item
Valid access levels
Min.
Units
Output signal
levels for
multi-function
analog outputs
Function
Display
Item
Flux
Vec-
tor
Open
Vec-
tor
V/f
w/PG
V/f
Min.
Units
Output signal
levels for
multi-function
analog outputs
Function
Display
U1-25
DI-16 Reference
Monitors the reference value from a
3G3FV-PDI16H2 Digital Command Card.
The value will be displayed in binary or
BCD depending on parameter F3-01.
Can’t be output.
---
A
A
A
A
U1-26
Voltage Ref (Vq)
Monitors the Inverter’s internal voltage
reference value for the motor’s secon-
dary current control.
10 V: 200 (400) VAC
(0 to
±
10 V possible)
0.1 V
X
X
A
A
U1-27
Voltage Ref (Vd)
Monitors the Inverter’s internal voltage
reference value for the motor’s excitation
current control.
10 V: 200 (400) VAC
(0 to
±
10 V possible)
0.1 V
X
X
A
A
U1-28
CPU ID
Manufacturer’s CPU software ID number
Can’t be output.
0.1 V
A
A
A
A
U1-32
ACR(q) Output
Monitor’s the current control output value
for the motor’s secondary current.
10 V: 100%
0.1%
X
X
A
A
U1-33
ACR(d) Output
Monitor’s the current control output value
for the motor’s excitation current.
10 V: 100%
0.1%
X
X
A
A
U1-34
OPE Detected
Displays the first constant number for
which an OPE error was detected.
Can’t be output.
---
A
A
A
A
U1-35
Zero Servo Pulse
Multiplies the number of PG pulses by
four to display the movement width at the
zero servo stop point.
Can’t be output.
1
X
X
X
A
U1-36
PID Input
PID ref PID reference bias – PID
feedback value
The max. frequency corresponds to
100%.
10 V:
Max. frequency
0.01
%
A
A
A
A
U1-37
PID Output
PID control output
The max. frequency corresponds to
100%.
10 V:
Max. frequency
0.01
%
A
A
A
A
U1-38
PID Setpoint
PID ref PID reference bias
The max. frequency corresponds to
100%.
10 V:
Max. frequency
0.01
%
A
A
A
A
Preparing for Operation
Chapter 3
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...