
6-69
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
E5-01
Motor Rated FLA
0.32 to
6.40
(see
note 4)
A
1.9 (see
note 3)
Advanced
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
E5-02
Motor Rated Slip
0.00 to
20.00
Hz
2.90 (see
note 3)
Advanced
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
E5-03
No-Load Current
0.00 to
2.90
(see
note 5)
A
1.20 (see
note 3)
Advanced
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
E5-04
Number of Poles
2 to 48
---
4
Not ap-
plicable.
Ad-
vanced
Not applica-
ble.
Ad-
vanced
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
E5-05
Term Resistance
0.000 to
65.000
Ω
9.842
(see note
3)
Advanced
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
E5-06
Leak Inductance
0.0 to
40.0
%
18.2 (see
note 3)
Not applicable.
Advanced
The above parameters are used to set the V/f characteristics and constants of the second motor. Set
them like the parameters E2-01 through E2-06 and E1-04 through E1-10.
Note 1. If the first motor and second motor are different to each other in maximum frequency setting,
the higher set value of them will be the set range of the frequency reference.
Note 2. The upper limit values and default settings are for 200-V class Inverter models. Double the
values for 400-V class Inverters.
Note 3. The default settings vary with the Inverter’s capacity or a change in the control mode. The
values for 200-V class, 0.4-kW Inverters are shown.
Note 4. The setting range is between 10% and 200% of the Inverter’s rated current. The value for
200-V class, 0.4-kW Inverters is shown.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...