Initialize Mode
The initialize mode is used to select the language displayed by the Unit, the access level,
and the control mode; it is also used to initialize the Unit’s parameters.
S
Selecting the Display Language
Use parameter A1-00 to select the language displayed by the Unit. Messages can be displayed in 0:
English, 1: Japanese, 2: German, 3: French, 4: Italian, 5: Spanish, or 6: Portuguese. This parameter is
not initialized by the initialize operation and it can be changed during operation.
Note The language that is set will be indicated on the display.
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
A1-00
Select Language
0 to 6
---
0
Quick-start, Basic, or Advanced
Example
The following example shows how to change parameter A1-00 so that Japanese is displayed instead of
English.
Key sequence
Display
Explanation
** Main Menu **
Operation
Displays operation mode.
** Main Menu **
Initialize
Displays initialize mode.
Select Language
English
Puts the Unit in initialize mode.
(Select Language display)
A1-00= 0
English
Displays the parameter setting for A1-00.
A1-00= 1 ***
FN]:^
Sets the display language to Japanese.
<^.3=3
67:P6]
Writes the new setting.
9^]:^
>]@8
FN]:^
Returns to the Select Language display.
S
Setting the Access Level
Use parameter A1-01 to select the parameter access level. This level determines which parameters
can be displayed and changed. (The parameters which can be displayed and changed also depend
upon the control mode being used.) This parameter can be changed during operation.
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
A1-01
Access Level
0 to 4
---
2
Quick-start, Basic, or Advanced
Preparing for Operation
Chapter 3
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...