3-13
Item
Valid access levels
Min.
Units
Output signal
levels for
multi-function
analog outputs
Function
Display
Item
Flux
Vec-
tor
Open
Vec-
tor
V/f
w/PG
V/f
Min.
Units
Output signal
levels for
multi-function
analog outputs
Function
Display
U1-11
Output Term Sts
(Output terminal
status)
Shows the ON/OFF status of outputs.
U1-11=00000000
1: Terminals 9–10 ON
1: Terminal 25 ON
1: Terminal 26 ON
Not used. (always 0)
1: Terminals 18/19–20
ON
Can’t be output.
---
Q
Q
Q
Q
U1-12
Int Ctl Sts 1
(Internal control
status)
Shows the Inverter’s operating status.
U1-12=00000000
1: Running
1: Zero-speed level
1: Reverse
1: Reset input ON
1: F.ref/F.out agree
1: Inverter ready
1: Minor fault detected
1: Major fault detected
Can’t be output.
---
Q
Q
Q
Q
U1-13
Elapsed Time
Monitors the Inverter’s elapsed operating
time.
The initial value and running/power-on
time selection can be set with parameters
o2-07 and o2-08.
Can’t be output.
1 hr
Q
Q
Q
Q
U1-14
FLASH ID
Manufacturer’s ID number
Can’t be output.
---
Q
Q
Q
Q
U1-15
Term 13 Level
(Terminal 13 input
voltage level)
Monitors the input voltage of the frequen-
cy reference (voltage).
An input of 10 V corresponds to 100%.
10 V: 100% (10 V)
(0 to
±
10 V possible)
0.1%
B
B
B
B
U1-16
Term 14 Level
(Terminal 14 input
current level)
Monitors the input current of the frequen-
cy reference (current).
An input of 20 mA corresponds to 100%.
10 V: 100% (20 mA)
(0 to +10 V output)
0.1%
B
B
B
B
U1-17
Term 16 Level
(Terminal 16 input
voltage level)
Monitors the input voltage of the multi-
function analog input.
An input of 10 V corresponds to 100%.
10 V: 100% (10 V)
(0 to
±
10 V possible)
0.1%
B
B
B
B
U1-18
Mot SEC Current
Monitors the calculated value of the mo-
tor’s secondary current (Iq). The motor’s
rated current corresponds to 100%.
10 V: Rated current
(0 to +10 V output)
0.1%
B
B
B
B
U1-19
Mot EXC Current
Monitors the calculated value of the mo-
tor’s excitation current (Id). The motor’s
rated current corresponds to 100%.
10 V: Rated current
(0 to +10 V output)
0.1%
X
X
B
B
U1-20
SFS Output
Monitors the output frequency after a soft
start. The display shows the frequency
without the correction from compensation
functions such as slip compensation.
10 V:
Max. frequency
(0 to
±
10 V possible)
0.01
Hz
A
A
A
A
U1-21
ASR Input
Monitors the input to the speed control
loop. The max. frequency corresponds to
100%.
10 V:
Max. frequency
(0 to
±
10 V possible)
0.01
%
X
A
X
A
U1-22
ASR Output
Monitors the output from the speed con-
trol loop. The motor’s rated current corre-
sponds to 100%.
10 V: Rated current
(0 to
±
10 V possible)
0.01
%
X
A
X
A
U1-23
Speed Deviation
Monitors the speed deviation within the
speed control loop. The max. frequency
corresponds to 100%.
10 V:
Max. frequency
(0 to
±
10 V possible)
0.01
%
X
A
X
A
U1-24
PID Feedback
Monitors the feedback value when PID
control is used. The input for the max.
frequency corresponds to 100%.
10 V:
Max. frequency
(0 to
±
10 V possible)
0.01
%
A
A
A
A
Preparing for Operation
Chapter 3
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...