If the output torque at low speed is a problem (i.e., a heavy load is connected at low speed), set the
parameter L8-18 to 1 and the parameter L8-19 to 0.
Note 1. Do not set both parameters (L8-17 and L8-19) to 0, otherwise the Inverter may be damaged.
In that case, use a higher rank Inverter with parameter L8-17 set to 0 and parameter L8-19 set
to 1.
Note 2. Use a higher rank Inverter or set parameter C6-01 (Carrier Freq Max) to 2 kHz if a high load is
continuously connected at low speed in flux vector control mode.
Settings for L8-17
Setting
Function
0
Disabled. (The carrier frequency is not reduced at low speed.)
1
Enabled. (The carrier frequency is reduced at low speed.)
2
For factory adjustment. (Do not use.)
3
y
j
(
)
Settings for L8-19
Setting
Function
0
Disabled. (The OL2 detection level is not reduced at low speed.)
1
Enabled (The OL2 detection level is reduced at low speed.)
6-5-9 Operator Parameters: o
H
Operator Display Selection (o1)
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
o1-01
User Monitor Sel
4 to 38
---
6
Basic or Advanced
Note This parameter can be changed during operation.
•
In operation mode, the frequency reference, output frequency, output current, and output voltage can
be monitored immediately if the default settings are being used. One of these four values, the output
voltage, can be changed to a different value. When you want to monitor a value other than the output
voltage, set that value’s number in parameter o1-01.
•
Use the last two digits from the “U1 Monitor” list (U1-
) to select a value. Refer to page 3-12 for a
table listing all of these U1 settings.
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
o1-02
Power-On Monitor 1 to 4
---
1
Basic or Advanced
Note This parameter can be changed during operation.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...