6-72
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
F2-01
AI-14 Input Sel
0, 1
---
0
Basic or Advanced
This parameter cannot be changed during operation.
Explanation of Settings
Setting
Description
0
3-channel individual input (CH1: terminal 13; CH2: terminal 14; CH3: terminal 16;
1
3-channel additional input (Sum of CH1 to CH3 is used as the frequency reference value.)
Parameter b1-01 (reference selection) must be set to “1” (external terminal), except for when 3-channel
input (setting: 0) is set.
When using a 3G3IV-PAI14B, the multi-function input “Option/Inverter selection” function (setting: 2)
cannot be used.
H
Setting a Digital Reference Card (F3)
When using a 3G3IV-PDI08/PD116H2 Digital Reference Card, set parameter b1-01 (reference selec-
tion) to “3” (option) and set the input method with parameter F3-01.
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
F3-01
DI Input
0 to 7
---
0
Basic or Advanced
This parameter cannot be changed during operation.
Explanation of Settings
Setting
Description
0
BCD 1% unit
1
BCD 0.1% unit
2
BCD 0.01% unit
3
BCD 1 Hz unit
4
BCD 0.1 Hz unit
5
BCD 0.01 Hz unit
6
BCD special setting (5-digit input)
(Only when 3G3FV-PDI16H2 is used.)
7
Binary input (Set value is displayed in decimal notation.)
•
When binary input is used (setting: 7), this becomes the maximum frequency (100% speed) reference
when all bits are set to “1.”
3G3IV-PD108:
Maximum frequency reference when FFH (255) is set.
3G3IV-PD116H2:
Maximum frequency reference when FFFH (4095) is set with 12 bits se-
lected. Maximum frequency reference when 7530H (30000) is set with 16 bits selected.
•
Setting 6, BCD special setting (5-digit input), is valid only when the 3G3IV-PD116H2 is used.
If the parameter o1-03 (Display Scaling) is set to 2 or a larger value, normal BCD setting will be valid and
the setting unit in the parameter o1-03 will be valid.
Setting:
1 to 5
Sign
8 x 10
3
4 x 10
3
2 x 10
3
1 x 10
3
to ...
8 x 10
0
4 x 10
0
2 x 10
0
1 x 10
0
Setting: 6 2 x 10
4
1 x 10
4
8 x 10
3
4 x 10
3
2 x 10
3
to ...
1 x 10
1
8 x 10
0
4 x 10
0
2 x 10
0
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...