7-6
Para
meter
No.
Page
Control mode
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Name
Para
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
control
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Display
name
b1-05
Operation
Selection
for
Minimum
Frequency
(E1-09 or
less)
Used to set the method of
operation when the frequency
reference input is less than the
minimum frequency (E1-09).
0:
Run at frequency reference
(E1-09 not effective).
1:
STOP (Frequencies below
E1-09 in the coast to stop
state.)
2:
Run at min. frequency.
(E1-09)
0 to 3
0
NO
X
X
X
A
5-33
Zero-Speed
Oper
(E1 09)
3:
Run at zero speed
(Frequencies below E1-09
are zero)
Note: This function is only avail-
able in with flux vector
control.
b1-06
Setting
Control In-
put Re-
sponsive-
ness
Used to set the responsiveness
of the control inputs
(forward/reverse and
multi-function inputs.)
0:
Two scans every 2 ms (Use
when connecting transistor
outputs )
0, 1
1
NO
A
A
A
A
5-11
Cntl Input
Scans
outputs.)
1:
Two scans every 5 ms (Use
when connecting contact
outputs or switches.)
b1-07
Operation
Selection
After
Switching
to Remote
Mode
Used to set the Operation mode
by switching to the Remote
mode using the Local/Remote
Key.
0:
Run signals that are input
during mode switching are
ignored. (Input Run signals
after switching the mode.)
0, 1
0
NO
A
A
A
A
---
LOC/REM
RUN Sel
after switching the mode.)
1:
Run signals become
effective immediately after
switching to the Remote
mode.
b1-08
Operation
for run
commands
in modes
other than
drive mode
Used to set the operation when
a run command is input in a
mode other than drive mode.
0:
Run command ineffective
(Ignore run command.
Switch to drive mode and
input the run command
again in order to run.)
1:
Run command effective
(Run according to run
d )
0, 1
0
NO
A
A
A
A
6-41
RUN CMD
at PRG
(
g
command.)
Note: Safety precautions are re-
quired when using the “1”
setting.
Note: The “1” setting is not valid
if b1-02 = 0.
Parameter Lists
Chapter 7
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...