3-15
Fault Trace
Item
Display
Function
Output signal
l
l f
Min.
U it
Valid access levels
e
sp ay
u c o
Ou pu s g a
levels for
multi-function
analog outputs
Units
V/f
V/f
w/PG
Open
Vec-
tor
Flux
Vec-
tor
U2-01
Current Fault
Information on the current fault
Can’t be output.
---
Q
Q
Q
Q
U2-02
Last Fault
Information on the last fault
Ca
be ou u
---
Q
Q
Q
Q
U2-03
Frequency Ref
Frequency reference value when the “last
fault” occurred.
0.01
Hz
Q
Q
Q
Q
U2-04
Output Freq
Output frequency when the “last fault” oc-
curred.
0.01
Hz
Q
Q
Q
Q
U2-05
Output Current
Output current when the “last fault” occurred.
0.1 A
Q
Q
Q
Q
U2-06
Motor Speed
Motor speed when the “last fault” occurred.
0.01
Hz
X
Q
Q
Q
U2-07
Output Voltage
Output voltage when the “last fault” occurred.
0.1 V
Q
Q
Q
Q
U2-08
DC Bus Voltage
The main circuit DC voltage when the “last
fault” occurred.
1 V
Q
Q
Q
Q
U2-09
Output kWatts
Output power when the “last fault” occurred.
0.1
kW
Q
Q
Q
Q
U2-10
Torque Reference
Torque reference when the “last fault” oc-
curred. (The rated torque = 100%.)
0.1%
X
X
Q
Q
U2-11
Input Term Sts
Input terminal status when the “last fault” oc-
curred. (Same format as U1-10.)
---
Q
Q
Q
Q
U2-12
Output Term Sts
Output terminal status when the “last fault”
occurred. (Same format as U1-11.)
---
Q
Q
Q
Q
U2-13
Inverter status
Inverter operating status when the “last fault”
occurred. (Same format as U1-12.)
---
Q
Q
Q
Q
U2-14
Elapsed time
Elapsed operating or power-on time when the
“last fault” occurred.
1 hr
Q
Q
Q
Q
Fault History
Item
Display
Function
Output signal
l
l f
Min.
U it
Valid access levels
e
sp ay
u c o
Ou pu s g a
levels for
multi-function
analog outputs
Units
V/f
V/f
w/PG
Open
Vec-
tor
Flux
Vec-
tor
U3-01
Last Fault
Information on the last fault.
Can’t be output.
---
Q
Q
Q
Q
U3-02
Fault Message 2
Information on the 2
nd
to last fault.
Ca
be ou u
---
Q
Q
Q
Q
U3-03
Fault Message 3
Information on the 3
rd
to last fault.
---
Q
Q
Q
Q
U3-04
Fault Message 4
Information on the 4
th
to last fault.
---
Q
Q
Q
Q
U3-05
Elapsed Time 1
Elapsed running or power-on time when the
last fault occurred.
1 hr
Q
Q
Q
Q
U3-06
Elapsed Time 2
Elapsed running or power-on time when the
2
nd
to last fault occurred.
1 hr
Q
Q
Q
Q
U3-07
Elapsed Time 3
Elapsed running or power-on time when the
3
rd
to last fault occurred.
1 hr
Q
Q
Q
Q
U3-08
Elapsed Time 4
Elapsed running or power-on time when the
4
th
to last fault occurred.
1 hr
Q
Q
Q
Q
Preparing for Operation
Chapter 3
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...