7-13
7-2-2 Tuning Parameters
H
Acceleration/Deceleration: C1
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
C1-01
Accelera-
tion time 1
Sets the acceleration time to
accelerate from 0 to the
i
f
i
0.0 to
6000.0
(S
10.0
OK
Q
Q
Q
Q
5-12,
5-18
Accelera-
tion Time 1
maximum frequency, in
1-second units.
(See
note.)
C1-02
Decelera-
tion time 1
Sets the deceleration time to
decelerate from the maximum
f
t 0 i 1
d
OK
Q
Q
Q
Q
5-12,
5-18
Decelera-
tion Time 1
frequency to 0, in 1-second
units.
C1-03
Accelera-
tion time 2
The acceleration time when the
multi-function input
“
lti
l/d
l ti
1” i
t
OK
B
B
B
B
5-12,
5-18
Accelera-
tion Time 2
“multi-accel/decel time 1” is set
to ON.
C1-04
Decelera-
tion time 2
The deceleration time when the
multi-function input
“
lti
l/d
l ti
1” i
t
OK
B
B
B
B
5-12,
5-18
Decelera-
tion Time 2
“multi-accel/decel time 1” is set
to ON.
C1-05
Accelera-
tion time 3
The acceleration time when the
multi-function input
“
lti
l/d
l ti
2” i
t
NO
A
A
A
A
5-12,
5-18
Accelera-
tion Time 3
“multi-accel/decel time 2” is set
to ON.
C1-06
Decelera-
tion time 3
The deceleration time when the
multi-function input
“
lti
l/d
l ti
2” i
t
NO
A
A
A
A
5-12,
5-18
Decelera-
tion Time 3
“multi-accel/decel time 2” is set
to ON.
C1-07
Accelera-
tion time 4
The acceleration time when the
multi-function input
“multi accel/decel time 1” and
NO
A
A
A
A
5-12,
5-18
Accelera-
tion Time 4
“multi-accel/decel time 1” and
“multi-accel/decel time 2” are
set to ON.
C1-08
Decelera-
tion time 4
The deceleration time when the
multi-function input
“multi accel/decel time 1” and
NO
A
A
A
A
5-12,
5-18
Decelera-
tion Time 4
“multi-accel/decel time 1” and
“multi-accel/decel time 2” are
set to ON.
C1-09
Emergency
stop time
The deceleration time when the
multi-function input “Emergency
(fast) stop” is set to ON.
NO
B
B
B
B
5-12,
5-18
Fast Stop
Time
(fast) sto is set to ON.
Note: This function can be used
as a stop method when a
fault has been detected.
C1-10
Accelera-
tion/decel-
eration time
units
0:
0.01-second units
1:
0.1-second units
0, 1
1
NO
A
A
A
A
5-11,
5-18
Acc/Dec
Units
Parameter Lists
Chapter 7
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...