6-24
•
Speed Limit Bias Setting
Parameter
Display name
Setting
Units Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
d5-05
Speed Lmt Bias
0 to 120
%
10
Not applicable.
Advanced
Note This parameter cannot be changed during operation.
Set the speed limit bias as a percentage of the maximum frequency. (The max. frequency is
100%.)
The speed limit bias can be used to add margins to the speed limit.
When the speed limit bias is used, it is possible to set the same speed limit value in both the for-
ward and reverse directions. For example, the following settings establish speed limits of 50% of
the maximum frequency in both the forward and reverse directions.
Speed limit setting: Zero (with d5-04 as the speed limit: d5-03 = 2, d5-04 = 0)
Speed limit bias setting: 50% (d5-05 = 50)
When a forward speed limit and a speed limit bias have been set, the speed range of the torque
control is from the “–speed limit bias setting” to the “speed limit s speed limit bias setting.” In
effect, the speed limit range is extended by the speed limit bias in both the forward and reverse
directions.
When the speed exceeds the reverse
speed limit, the torque is increased in
the forward direction.
Reverse
rotation
Forward
rotation
Motor speed
Torque reference value
Output torque
Forward
direction
Reverse
direction
When the speed exceeds the forward
speed limit, the torque is increased in
the reverse direction.
Effective range of
torque control
Speed limit setting
Limit opposite
to speed limit
setting
d5-05
d5-05
H
Torque Reference Adjustment
D
Primary Delay Time Constant for Torque Reference Filter
•
The time constant of the primary filter in the torque reference section can be adjusted.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...