6-93
D
Zero-servo End (Setting: 33)
OFF
The zero-servo command isn’t being input or zero-servo position control hasn’t been completed.
ON
The position has been brought within the zero servo completion width (b9-02) after the zero servo
command was input.
•
This output function indicates that zero-servo position control has been completed.
•
The output is turned ON after the zero servo command is input and the difference between the zero-
servo operation starting position and the current position is within the zero servo completion width
(b9-02).
H
Multi-function Analog Input/Frequency Reference (Current)
(H3-05/H3-09)
D
Parameter Settings
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
H3-05
Terminal 16 Sel
0 to 1F
---
1F
Basic or Advanced
H3-09
Terminal 14 Sel
1 to 1F
---
1F
Advanced
Note These parameters cannot be changed during operation.
Setting
Function
Equivalent of 100% Input
(10 V
20
A)
Control mode
g
q
p
(10 V or 20 mA)
V/f
V/f
w/PG
Open-loop
Vector
Flux
Vector
0
Auxiliary reference (H3-05)
Maximum frequency
OK OK
OK
OK
1
Frequency Gain
Frequency ref. of terminal 13
OK OK
OK
OK
2
Frequency Bias
Maximum frequency
(added to H3-03)
OK OK
OK
OK
4
Voltage Bias
Rated voltage (E1-05)
OK OK
OK
OK
5
Accel/Decel Change
Accel/Decel times (C1-
)
OK OK
OK
---
6
DC Brake Current
Inverter’s rated output current
OK OK
OK
OK
7
Overtorque Level
Rated torque or Inverter’s
rated output
(Setting in L6-05 is ignored.)
OK OK
---
---
8
Stall Prevention Level
Inverter’s rated output current
OK OK
OK
OK
9
Reference Lower Limit
Maximum frequency
OK OK
OK
OK
A
Jump Frequency
Maximum frequency
OK OK
OK
OK
B
PID Feedback
Maximum frequency
OK OK
OK
OK
C
PID target value
Maximum frequency
OK OK
OK
OK
D
Frequency bias 2
Maximum frequency (added
to H3-03 set value)
OK OK
OK
OK
10
Forward Torque Limit
Rated torque
---
---
OK
OK
11
Reverse Torque Limit
Rated torque
---
---
OK
OK
12
Regenerative Torque Limit
Rated torque
---
---
OK
OK
13
Torque reference
Rated torque
---
---
---
OK
14
Torque Compensation Bias
Rated torque
---
---
---
OK
15
Speed Limit
Rated torque
---
---
OK
OK
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...