6-58
The relation between these parameters is shown in the following diagram.
Output frequency
Time
b6-04
b6-02
b6-01
b6-03
6-5-3 Tuning Parameters (C)
H
Setting the S-curve Characteristic Function (C2)
•
Using the S-curve characteristic function for acceleration and deceleration can reduce shock to the
machinery when stopping and starting.
•
With the SYSDRIVE 3G3FV, S-curve characteristic times can be set respectively for beginning accel-
eration, ending acceleration, beginning deceleration, and ending deceleration.
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
C2-01
SCrv Acc @ Start 0.00 to
2.50
Sec
0.20
Advanced
C2-02
SCrv Acc @ End
0.00 to
2.50
Sec
0.20
Advanced
C2-03
SCrv Dec @
Start
0.00 to
2.50
Sec
0.20
Advanced
C2-04
SCrv Dec @ End
0.00 to
2.50
Sec
0.20
Advanced
These parameters cannot be changed during operation.
•
The relation between these parameters is shown in the following diagram.
Output frequency
Time
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...