6-85
S
Acceleration/Deceleration Ramp Hold (Setting: A)
S
UP and DOWN Commands (Settings: 10 and 11)
S
Trim Control Increase and Decrease (Settings: 1C and 1D)
S
Analog Frequency Reference Sample/Hold (Setting: 1E)
D
Analog Frequency Reference Sample/Hold (Setting: 1E)
This function retains the analog input in the Inverter.
•
If the analog frequency reference sample/hold input is ON for 100 ms continuously, the analog value
that is input 100 ms after the analog frequency reference sample/hold input turns ON will be sampled
and retained.
•
The retained analog value will be kept on hold until the next sampling period.
•
All the following analog inputs are applicable.
Frequency reference input (voltage): Pin 13
Frequency reference input (current): Pin 14
Multi-function analog input: Pin 16
Analog Input Cards: 3G3IV-PAI14U/3G3IV-PAI14B
Note Select and set one of the following functions for multi-function input. Do not set more than one of
them, otherwise a setting error (OPE3) will result.
S
Acceleration/Deceleration Ramp Hold (Setting: A)
S
UP and DOWN Commands (Settings: 10 and 11)
S
Trim Control Increase and Decrease (Settings: 1C and 1D)
S
Analog Frequency Reference Sample/Hold (Setting: 1E)
Sample/hold
command
Analog input
Frequency reference (hold value)
Analog output and
frequency refer-
ence (hold value)
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...