6-41
Group
Control mode
Comments
Function
Group
Flux
Vector
Open-loop
Vector
V/f
w/PG
V/f
Comments
Function
Terminal
H1
Digital Inputs
S
Function selection for multi-function inputs
OK
OK
OK
OK
e
a
H2
Digital Outputs
S
Function selection for multi-function outputs
OK
OK
OK
OK
H3
Analog Inputs
S
Adjustment/function selection for external analog in-
puts
OK
OK
OK
OK
H4
Analog Outputs
S
Adjustment/function selection for multi-function analog
outputs
OK
OK
OK
OK
H5
Serial Com Setup
Not Used. (Do not change this setting.)
---
---
---
---
Protection
L1
Motor Overload
S
Sets electrical/thermal functions that protect the motor.
OK
OK
OK
OK
o ec o
L2
PwrLoss Ridethru
S
Selects the power-loss processing method.
OK
OK
OK
OK
L3
Stall Prevention
S
Accel/Decel stall prevention settings and selection
OK
OK
OK
OK
L4
Ref Detection
S
Frequency detection settings and selection
OK
OK
OK
OK
L5
Fault Restart
S
Fault restart function settings
OK
OK
OK
OK
L6
Torque Detection
S
Sets overtorque detection functions 1 and 2
OK
OK
OK
OK
L7
Torque Limit
Torque limit settings
---
---
OK
OK
L8
Hdwe Protection
S
Hardware overheating and phase loss protection set-
tings
OK
OK
OK
OK
Operator
o1
Monitor Select
S
Selects the Operator’s display and setting methods.
OK
OK
OK
OK
O e a o
o2
Key Selections
S
Operator’s key function selection and other parame-
ters
OK
OK
OK
OK
6-5-2 Application Parameters (b)
H
Setting Operation Source Selection (b1)
•
The input methods of parameters or frequency references and the operation methods of the run com-
mand can be set in the Inverter in operation mode. In addition, the following advanced functions are
available.
•
The run command already set in the Inverter can be disabled or enabled when switching the Inverter to
local mode from remote mode.
•
The run command already set in the Inverter in any mode other than drive mode can be disabled or
enabled.
•
Set the parameter according to the application.
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
b1-07
LOC/REM RUN
Set
0, 1
---
0
Advanced
Explanation of Settings
Setting
Description
0
The run command already set is disabled (when the Inverter is switched to local mode
from remote mode. The Inverter will start operating with the run command input again.)
1
The run command already set is enabled (and the Inverter will start operating according
to the present run command when the Inverter is switched to local mode from remote
mode).
Note If parameter b1-07 (LOC/REM RUN Sel) is set to 1, the run command will not be ignored. In this
case, an Inverter may start operating immediately when switched to remote mode from local
mode. Take necessary measures for safety.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...