9-28
D
Standard Models
Maximum
li
bl
200-V class
400-V class
applicable
motor
Inverter
capacity
Output Noise Filter
Inverter
capacity
Output Noise Filter
motor
capacity
(kW)
capacity
(kVA)
Model (3G3IV-)
Rated
current (A)
capacity
(kVA)
Model (3G3IV-)
Rated
current (A)
0.4
1.2
PLF310KA
10
1.4
PLF310KB
10
0.75
2.3
PLF310KA
10
2.6
PLF310KB
10
1.5
3.0
PLF310KA
10
3.7
PLF310KB
10
2.2
4.2
PLF310KA
10
4.7
PLF310KB
10
3.7
6.7
PLF320KA
20
6.1
PLF310KB
10
5.5
9.5
PLF350KA
50
11
PLF320KB
20
7.5
13
PLF350KA
50
14
PLF320KB
20
11
19
PLF350KA x 2P
100
21
PLF335KB
35
15
24
PLF350KA x 2P
100
26
PLF335KB
35
18.5
30
PLF350KA x 2P
100
31
PLF345KB
45
22
37
PLF350KA x 3P
150
40
PLF375KB
75
30
50
PLF350KA x 3P
150
50
PLF375KB
75
37
61
PLF3110KB x 2P
220
61
PLF3110KB
110
45
70
PLF3110KB x 2P
220
73
PLF3110KB
110
55
85
PLF3110KB x 3P
330
98
PLF375KB x 2P
150
75
110
PLF3110KB x 4P
440
130
PLF3110KB x 2P
220
110
---
---
---
170
PLF3110KB x 3P
330
160
---
---
---
230
PLF3110KB x 4P
440
185
---
---
---
260
PLF3110KB x 4P
440
220
---
---
---
340
PLF3110KB x 5P
550
300
---
---
---
460
PLF3110KB x 6P
660
Specifications
Chapter 9
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...