7-12
H
Energy Saving: b8
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
b8-01
Energy-
saving gain
Sets the Inverter output voltage
when the energy-saving
command is input.
Note: Enabled when the “ener-
0 to
100
80
NO
A
A
X
X
6-13,
6-38
Energy
Save Gain
Note: Enabled when the ener-
gy-save mode” command
is set for multi-function in-
put. Set as a percentage
of the V/f pattern voltage.
b8-02
Energy-
saving fre-
quency
Sets the energy-saving effective
range minimum frequency in
Hz.
Note: The energy-saving func-
tion is only enabled when
0.0 to
400.0
0.0
NO
A
A
X
X
6-13,
6-38
Energy
Save Freq
tion is only enabled when
the frequency is greater
than the energy-saving
frequency and the speeds
are consistent.
H
Zero Servo: b9
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
b9-01
Zero-servo
gain
Used to adjust the strength of
the zero-servo lock.
Note: Enabled when the “zero-
servo command” is set for
the multi-function input.
When the zero-servo
command has been input
and the frequency refer-
ence drops below excita-
0 to
100
5
NO
X
X
X
A
6-19
Zero Servo
Gain
ence dro s below excita-
tion level (b2-01), a posi-
tion control loop is
created and the motor
stops. Increasing the
zero-servo gain in turn in-
creases the strength of
the lock. Increasing it by
too much will cause vibra-
tion.
b9-02
Zero-servo
completion
width
Sets the output width of the
P-lock completion signal.
Note: Enabled when the “zero-
servo completion (end)” is
set for multi-function out-
put. The zero-servo
completion signal is ON
when the current position
is within the range (the
zero servo position
±
0 to
16383
10
NO
X
X
X
A
6-19
Zero Servo
Count
g (
zero-servo position
±
zero-servo completion
width.)
Set the allowable position
displacement from the
zero-servo position to 4
times the pulse rate of the
PG (pulse generator, en-
coder) in use.
Parameter Lists
Chapter 7
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...