7-23
H
Sequence for Reference: d4
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
d4-01
Reference
frequency
hold
function
selection
Sets whether or not frequencies
on hold will be recorded.
0:
Disabled (when operation is
stopped or the power is
turned on again starts at 0.)
1:
Enabled (when operation is
stopped or the power is
turned on again starts at the
previous hold frequency.)
Note: This function is available
0, 1
0
NO
A
A
A
A
6-65
MOP Ref
Memory
Note: This function is available
when the multi-function
inputs “accel/decel Ramp
Hold” or “UP/DOWN”
commands (MOP
increase/decrease) are
set.
d4-02
Trim control
level
Sets the increase/decrease
frequency for analog frequency
references as a percentage of
the maximum frequency.
Note: This function is available
0 to
100
25
NO
A
A
A
A
6-66
Trim
Control Lvl
Note: This function is available
when the multi-function
inputs “Trim Ctl Increase”
or “Trim Ctl Decrease” is
set.
H
Torque Control: d5
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
d5-01
Torque con-
trol selec-
tion
0:
Speed control (C5-01 to
C5-07)
1:
Torque control
Note: This function is only avail-
able in flux vector control
mode.
To use the function for
0, 1
0
NO
X
X
X
A
6-20,
6-27
Torq Con-
trol Sel
To use the function for
switching between speed
and torque control, set to
0 and set the multi-func-
tion input to “speed/torque
control change.”
d5-02
Torque ref-
erence
delay time
Sets the torque reference delay
time in ms units.
Note: This function can be used
to adjust the noise of the
torque control signal or
the responsiveness with
0 to
1000
0
NO
X
X
X
A
6-25
Torq Ref
Filter
g
the responsiveness with
the host controller. When
vibration occurs during
torque control, increase
the set value.
Parameter Lists
Chapter 7
Summary of Contents for SYSDRIVE 3G3FV
Page 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Page 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Page 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Page 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Page 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Page 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Page 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...