Instruction Manual 

Sku: TruPower-CContr-12V30A 

 

Solar Charge Regulator is designed to control the charging from solar panel into battery, and the 

power draw from the battery to outputs. 

 

Feature 

 

TPS555 Solar Charge Regulator is able to handle charge and discharge from either 12V battery or 
24V battery (Different Model required). 

 

It provides over-charging, over-discharging, short circuit, over-load and reverse polarity protection. 
Therefore keep the whole solar system at proper working condition. 

 

This solar charge regulator uses the latest Microcomputer-chip to realize intelligence control 

 

PWM (pulse width modulation) charging circuit is used for higher efficiency 

 

Big LCD display available for easy monitoring 

 

Technical data: 

Item 

12V battery Version 
(TPS555-1230) 

24V battery Version 
(TPS555-2430) 

Max. Solar Input current 

30A 

30A 

Max. Solar Voltage Input (Voc) 

50V 

50V 

Max. load current 

30A 

30A 

Over charge voltage 

14.5V±0.2V 

29V±0.2V 

Over discharge voltage 

10.7V±0.2V 

21.4 V±0.2V 

No-load loss 

18mA 

18mA 

Voltage loss charging Circuit 

 

≤0.4V 

≤0.4V 

Voltage loss of discharging circuit 

≤0.2V 

≤0.2V 

Operating temperature 

-25

-60

   

-25

-60

   

 

 

How to Charge: 

 

Connect Solar module, Rechargeable battery, and Load (if any) as describe in the diagram at 
end of this manual   
*    Please always connect with the sequence of: Battery 

 Solar module 

 Load 

*    Please always disconnect with the sequence of: Solar module 

 Load 

 Battery. 

      Switch off load before disconnecting.   
*    Please make sure that the connection to this charge regulator is tight and secure. 
*    Please make sure you connect with correct polarity (“+” for positive & “—” for negative) 
*    Please make sure the solar panel and load connected to this charge regulator is within the 
      limits stated in the technical data sheet above 