XSNet 1600 MC 

 

10/100Base to 100Base-FX media converter 

 

USER MANUAL 

 
1. General description 
 

The XSNet 1600 Series 10/100 to 100Base-FX 
Media Converters allow incorporation of a copper-
based Ethernet 10/100Base-TX into a fibre-optic 
100Base-FX Fast. They use store-and-forward at 
full wire speed, and are compatible with other 
10Base-T & 100Base-TX/FX devices. The 1600 
MC connects to two multimode fibres, the 1640 
MC uses two single-mode fibres and the 1650 MC 
needs only one single-mode fibre. 
In full-duplex mode, this converter can span 
distances of up to 2 kilometres for multimode fibre 
and up to 100 kilometres for long-haul single-mode 
fibre between networking devices. 
 
Auto-negotiation (N-Way support), manual half- or 
full-duplex mode on the fibre port, 

manual half/full-

duplex mode and speed selection on the copper 
port, Link Fault Signalling (LFS) and both Remote 
and local loopback Test can be selected via DIP 
switches. The automatic MDI detection setting 
feature allows for automatic cable type 
configuration when establishing a connection 
between RJ45 ports. 
Front panel LEDs provide instant information about 
the device's network and connectivity status. 
An XSNet 1600 MC series converter, housed in a 
compact stand-alone box which can also be 
mounted on a vertical surface, is powered with an 
230 V

AC

/12 V

DC

 adapter, which is included in the 

package, together with rubber feet and mounting 
screws. 

 
 

O

FF

O

FF

O

FF

O

FF

FD

10

0

FD

O

N

O

N

O

N

O

N

H

D

10

H

D

PWR

12 V DC
800 mA

LNK/ACT LFS

FDX/COL 100

TX                   RX

Figure 1. Media converter front panel (top), rear 

panel (middle) and top view with double optical 

connector (keyed holes are on bottom side). 

50

25

110

74

12

Summary of Contents for XSNet 1600 MC

Page 1: ...ode on the fibre port manual half full duplex mode and speed selection on the copper port Link Fault Signalling LFS and both Remote and local loopback Test can be selected via DIP switches The automatic MDI detection setting feature allows for automatic cable type configuration when establishing a connection between RJ45 ports Front panel LEDs provide instant information about the device s network...

Page 2: ... 4 rubber feet included in the package Alternatively the two screws included may be used to affix the unit to a vertical flat surface fitting the screws heads in the two keyholes in the converters bottom side Please observe the following precautions do not expose the unit to heat moisture or dust or similar detrimental influences keep some free space around the unit for air circulation there are v...

Page 3: ... follow standard safety procedures in addition to the safety precautions and warnings specified in this manual and that this unit be installed in locations accessible to trained service personnel only Optelecom NKF assumes no liability for the customer s failure to comply with any of these safety requirements UL IEC EN 60950 1 General safety requirements The equipment described in this manual has ...

Page 4: ...nside or outside the equipment could cause the equipment to be more prone to fail EMC requirements Non video signal lines must use appropriate shielded CAT5 cabling S FTP or at least an equivalent If system components such as cabling e g coaxial cable data audio cc wiring and or the units are used outdoors ensure that all electrically connected components are carefully earthed and protected agains...

Reviews: