Installation and Operation Manual

Solis Three Phase Inverter

(75-110kW)

Ver 1

.

4

Ginlong Technologies Co., Ltd.

Ginlong Technologies Co., Ltd.

No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, 

Zhejiang, 315712, P.R.China.

Tel: +86 (0)574 6578 1806

Fax: +86 (0)574 6578 1606

If you encounter any problem on the inverter, please find out the inverter S/N 

and contact us, we will try to respond to your question ASAP. 

Please adhere to the actual products in case of any discrepancies in this user manual. 

Summary of Contents for Solis-100K-HV-5G

Page 1: ...tong Road Binhai Industrial Park Xiangshan Ningbo Zhejiang 315712 P R China Tel 86 0 574 6578 1806 Fax 86 0 574 6578 1606 If you encounter any problem on the inverter please find out the inverter S N and contact us we will try to respond to your question ASAP Please adhere to the actual products in case of any discrepancies in this user manual ...

Page 2: ... Settings Technicians Only 39 7 5 1 Selecting Standard 39 7 5 2 Grid ON OFF 40 7 5 3 Clear Energy 40 7 5 4 Reset Password 41 7 5 5 Power control 41 7 5 6 Calibrate Energy 41 7 5 7 Special Settings 42 7 5 8 STD Mode settings 42 7 5 9 Restore Settings 42 7 5 10 HMI Update 43 7 5 11 External EPM Set 43 7 5 12 Restart HMI 43 7 5 13 Debug Parameter 44 7 5 15 DSP Update 45 7 5 16 Compensation Set 45 7 5...

Page 3: ...ower that can satisfy local loads as well as feed the power distribution grid This manual covers the three phase inverter model listed below Solis 75K 5G Solis 80K 5G Solis 100K HV 5G Solis 110K BHV 5G Buttons LED LCD Screen Vent COM DC Inputs DC Switch AC Output COM Inverter packing list Part 1 2 Description Inverter Mounting Bracket Number 1 1 Hexagon bolt M6 12 Remarks 3 4 5 Fastening screw 2 D...

Page 4: ...inal box to repackage the inverter seal with adhesive tape with the desiccant inside the box Store the inverter in a clean and dry place free of dust and dirt The storage temperature must be between 40 70 and humidity should be between 0 to 100 non condensing Do not stack more than two 2 inverters high on a single pallet Do not stack more than 2 pallets high Keep the box es away from corrosive mat...

Page 5: ...perature of the inverter heat sink can reach 75 The inverter is designed to work in an ambient temperature range between 25 to 60 If multiple inverters are installed on site a minimum clearance of 500mm should be kept between each inverter and all other mounted equipment The bottom of the inverter should be at least 500mm above of the ground or floor see Figure 3 1 The LED status indicator lights ...

Page 6: ...ctricity supply the sound level from the inverter can be quite high 3 2 Product handling Figure 3 3 Handles used to move the inverter shown circled in red 3 1 2 4 Air circulation Do not install in small closed rooms where air cannot freely circulate To prevent overheating always ensure that the air flow around the inverter is not blocked Please review the instruction below for handling the inverte...

Page 7: ...ed vertically The steps to mount the inverter are listed below 1 Refer to Figure 3 6 drill holes for mounting screws based on the hole diameter of bracket using a precision drill keeping the drill perpendicular to the wall Max depth is 90mm 2 Make sure the bracket is horizontal And the mounting holes in Figure 3 6 are marked correctly Drill the holes into wall at your marks 3 3 1 Wall mounting 3 U...

Page 8: ...ees from vertical Figure 3 10 Wrong installation Angle The steps to mounted to the rack are listed below 3 Install mounting plate 1 Remove the bracket and fasteners from the packaging Mark the position for hole drilling according to the hole positions of the bracket Figure 3 11 Mark the position for hole 2 Drill the marked holes It is recommended to apply anti corrosive paint at the hole for corro...

Page 9: ...C OFF 2 Switch the DC Isolator OFF 3 Connect the inverter to the grid 4 Assemble PV connector and connect to the Inverter Inverter design uses PV style quick connect terminal The top cover needn t be opened during DC electrical connection The labels located the bottom of the inverter are described below in table 3 1 All electrical connections are suitable for local or national standard Table 3 1 E...

Page 10: ...unding 2 Prepare OT terminals M10 To effectively protect the inverter two grounding methods must be performed Connect the AC grounding cable Please refer to section 3 4 3 Connect the external grounding terminal 1 Prepare the grounding cable recommend to use the outdoor copper core cable The grounding wire should be at least half size of the hot wires To connect the grounding terminal on the heat s...

Page 11: ...G MAKE SURE the polarity of the PV array output conductors matches the DC and DC terminal labels before connecting these conductors to the terminals of the inverter 5 Measure PV voltage of DC input with multimeter verify DC input cable polarity see figure 3 22 and ensure each string voltage is in range of inverter operation Connect DC connector with inverter until hearing a slight clicking sound i...

Page 12: ...vice must be used between the inverter and the grid Table 3 2 Rating of grid OCPD 3 4 3 1 Connecting the inverter to the utility grid All electrical installations must be carried out in accordance with the local standards and the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 The AC and DC electric circuits are isolated from the enclosure If required by section 250...

Page 13: ...e terminal crimping area 2 Strip the insulation of the wire past the cable crimping area of the OT terminal then use a hydraulic crimp tool to crimp the terminal The crimped portion of the terminal must be insulated with heat shrinkable tube or insulating tape 1 Strip the end of AC cable insulating jacket about 300mm then strip the end of each wire NOTE If chosing aluminum alloy cable you must use...

Page 14: ...on terminals on the inverters COM1 is a 4 pin connector reserved for WiFi Cellular datalogger COM2 and COM3 are RS485 connection between inverters and both RJ45 and Terminal block are provided for use Inverter PV Strings Inverter PV Strings Inverter PV Strings Inverter PV Strings Grid Transformer PLC CCO Datalogger DC AC PLC RS485 PLC is available for multiple inverter monitoring One of the RS485 ...

Page 15: ...he main screen on the display select ENTER There are 4 sub menu options use the UP DOWN arrows to highlight ADVANCED SETTINGS Press enter to select 2 The screen will show that a password is required The default password is 0010 press the DOWN key to move cursor press the UP key to change the highlighted digit Figure 5 1 Information Settings Figure 5 2 YES ENT NO ESC Password 0000 3 Use the UP DOWN...

Page 16: ...ion in reverse polarity may damage these protection circuits and or the inverter 5 4 3 2 Leakage to ground 5 4 3 2 1 Detection of leakage to ground Solis inverters are transformer less and do not have an array connection to ground Any measurement of a fixed voltage between ground and either the positive or negative string wiring indicates a leakage ground fault to ground and must be corrected prio...

Page 17: ...rocedure To stop the inverter it is mandatory that the steps below are followed in the exact order outlined 1 Switch AC switch OFF 2 Wait approximately 30 seconds during this time the AC side capacitors are dissipating energy If the inverter has DC voltage above the start up threshold the red POWER LED will be lit Switch the DC switch OFF 3 Confirm all LED s switch OFF one 1 minute CAUTION Althoug...

Page 18: ...Normal operation I_DC01 05 0A I_DC02 04 9A I_DC20 05 2A VPV_Total Shows input voltage total IPV_Total Shows input current total Table 7 1 Information list Status Generating Power 1488W Grid Frequency F_Grid 50 06Hz Total Energy 0258458 kwh This Month 0123kwh Last Month 0123kwh Today 15 1kwh Yesterday 13 5kwh 10 sec 10 sec 10 sec 10 sec 10 sec 10 sec Status Shows instant status of the Inverter Powe...

Page 19: ...maintaince person to get running message such as internal temperature Standard No 1 2 etc Screens can be scrolled manually by pressing the UP DOWN keys 7 4 Advanced Info Technicians Only NOTE To access to this area is for fully qualified and accredited technicians only Enter menu Advanced Info and Advanced settings need password Select Advanced Info from the Main Menu The screen will require the p...

Page 20: ...ction the limits can be changed manually These voltage values are the phase voltage The display shows the latest warn messages see Figure 7 15 Screens can be scrolled 100 manually by pressing the UP DOWN keys Press the ESC key to return to the previous menu Msg000 T 00 00 00 00 D 0000 Figure 7 15 Warning Message 7 4 9 Warning Message 7 4 8 Communication Data The screen shows the internal data of t...

Page 21: ...the cursor Press the UP key to revise the value Press the ENTER key to execute the setting Press the ESC key to return to the previous menu OV G V1 300 480V OV G V1 T 0 01 9S OV G V2 300 490V OV G V2 T 0 01 1S UN G V1 173 336V UN G V1 T 0 01 9S UN G V2 132 319V UN G V2 T 0 01 1S Startup T 10 600S OV G F1 50 2 63Hz OV G F1 T 0 01 9S OV G F2 51 63Hz OV G F2 T 0 01 9S UN G F1 47 59 5Hz UN G F1 T 0 01...

Page 22: ...ode Settings 1 Working Mode Set 2 Power Rate Limit 3 Freq Derate Set 4 10mins Voltage Set 5 Power Priority 6 Initial Settings 7 Voltage PCC Set Selecting STD Mode Settings displays the sub menu shown below 7 5 7 Special Settings This function is applicable by maintenance personnel only wrong operation will prevent the inverter from reaching maximum power This function is applicable by maintenance ...

Page 23: ...uded Power Parameter and Voltage Parameter YES ENT NO ESC Power para 1 000 7 5 13 Debug Parameter 7 5 14 FAN Test This section is applicable to maintenance personnel only Figure 7 24 Debug Parameter as shown as below This section is applicable to maintenance personnel only Press the UP DOWN keys to scroll through items Press the ENTER key to select Press the DOWN key to scroll and press the UP key...

Page 24: ...e will start creating 450 Vdc between PV and ground No need any control or settings The Anti PID module repairs the PID effect of the PV model at night When operating the inverter LCD screen displays PID repairing information and the red light is on The Anti PID function is always ON when AC is applied If maintenance is required and turn off the AC switch can disable the Anti PID function 7 5 17 I...

Page 25: ...sage OV G V01 02 03 04 OV G F01 02 UN G F01 02 G IMP NO GRID OV DC01 02 03 04 OV BUS UN BUS01 02 GRID INTF01 02 OV TEM Failure description Over grid voltage Under grid voltage Over grid frequency Under grid frequency High grid impedance No grid voltage Over DC voltage Over DC bus voltage Under DC bus voltage Grid interference Over Temperature Solution 1 Resistant of AC cable is too high Change big...

Page 26: ...f the LED status indicator lights Other readings obtained from the Information submenu refer to Section 6 2 will also be helpful 5 The PV array configuration e g number of panels capacity of panels number of strings etc 6 Your contact details AFCI self detection model with AFCI module AFCI module self detect fault 1 Restart inverter or connect technician Arcing protection model with AFCI module De...

Page 27: ...6006 UNE 206007 1 IEC61727 DEWA Solis 80K 5G Safty EMC standard IEC 62109 1 2 IEC62116 EN 61000 6 2 4 10 Specifications 2W AC connection Grid connection standard DC connection Display Communication connections Warranty MC4 connector OT Terminal max 185 mm LCD 2 20 Z RS485 Optional Wifi GPRS PLC 5 years extand to 20 years VDE AR N 4105 VDE V 0124 VDE V 0126 1 1 UTE C15 712 1 NRS 097 1 2 G98 G99 EN ...

Page 28: ... DEWA Solis 110K BHV 5G Safty EMC standard IEC 62109 1 2 IEC62116 EN 61000 6 2 4 2W Dimensions W H D Weight 1050 567 314 5mm with AC switch 82kg 3 PE 480 Max DC input voltage Volts MPPT voltage range Volts Max input current Amps MPPT number Max input strings number Rated grid voltage Volts Rated grid output current Amps Max output current Amps Power Factor at rated output power Max efficiency EU e...