background image

HYBRID INVERTER

SOLAR/STORAGE/WIND/

BACK-UP GENERATOR 

USER MANUAL 

BPE-HI-3.6K & BPE-HI-5K

Summary of Contents for BPE-HI-3.6K

Page 1: ...HYBRID INVERTER SOLAR STORAGE WIND BACK UP GENERATOR USER MANUAL BPE HI 3 6K BPE HI 5K...

Page 2: ...10 Single phase parallel connection diagram 3 11Three phase Parallel Inverter 4 OPERATION 4 1 Power ON OFF 4 2 Operation and Display Panel 5 LCD Display Icons 5 1 Main Screen 5 2 Solar Power Curve 5 3...

Page 3: ...gramme the time of use settings selecting Time Of Use will allow the battery to be discharged to the load until a user set SOC is reached during the pre set 6 time periods You can also select whether...

Page 4: ...parts and even cause an explosion Please follow the installation procedure when you want to disconnect AC or DC terminals Please refer to Installation section of this manual for details Grounding ins...

Page 5: ...erformance Time of use function Smart Load Function Parallel function On Grid Off Grid 2 3 Basic System Architecture The following illustration shows basic application of this inverter It also include...

Page 6: ...stall this inverter at eye level in order to allow the LCD display to be read at all times Chart 3 1 Parts List 3 2 Mounting instructions Installation Precaution This Hybrid inverter is designed for o...

Page 7: ...follow the below steps to implement battery connection 1 Please choose a suitable battery cable with the correct connector which can fit into the battery terminals 2 Use a suitable screwdriver to uns...

Page 8: ...ut connection be sure to open the DC protector or disconnecter first 2 Remove 10mm of the insulation sleeve unscrew the bolts insert the AC input cables according to polarities indicated on the termin...

Page 9: ...ant for system safety and efficient operation to use the appropriate cable for PV module connection To reduce risk of injury please use the recommended cable size as below Be sure that the AC power so...

Page 10: ...tive conductor fails 3 8 WIFI Connection For the configuration of the Wi Fi Plug please refer to illustrations of the Wi Fi Plug at the end of this user manual Battery Solar Breaker CAN Breaker Breake...

Page 11: ...er Inverter No 3 slave Ground Inverter No 2 slave Inverter No 1 master Battery pack L wire CAN N wire PE wire Battery pack Grid CAN L1 L2 L3 N PE Load GEN Grid Load GEN Grid Load GEN Grid Inverter No...

Page 12: ...rt from grid Battery power negative means charge positive means discharge 4 OPERATION 4 1 Power ON OFF Once the unit has been correctly installed and the batteries are connected simply press the On Of...

Page 13: ...d When GEN PORT is utilised as Smart load output Power 0W Stand by 0 0Hz Energy CT1 0W L1 0V L2 0V Import Today 0 0KWH Total 8 60 KWH Today 2 2KWH Total 11 60 KWH Export LD1 0W CT2 0W LD2 0W Grid Grid...

Page 14: ...0A 30 6C 52 0 26 0Ah 0 0V 0 0A 0 0 0 50 33V 19 10A 31 0C 51 0 25 5Ah 53 2V 25 0A 0 0 0 50 30V 16 90A 30 2C 12 0 6 0Ah 53 2V 25 0A 0 0 0 4 5 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C...

Page 15: ...57 6V Equalization V 58 8V Equalization Days Shutdown Low Batt Restart TEMPCO mV C Cell Batt Resistance 90 days Equalization Hours 2 0 hours 25mOhms Battery Settings Set3 Batt Time Of Use Time System...

Page 16: ...R smart load output OR micro inverter input Generator Input If connected to a generator Gen connected to Grid input In off grid applications the generator can also be connected to the Grid input port...

Page 17: ...0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0...

Page 18: ...Information Error Code Diagnosis and Solution F13 F18 F20 F23 F24 F26 F30 F35 F41 F42 Inverter working mode change please wait one minute Working_Mode_change AC side over current fault Please check th...

Page 19: ...or operation Damage caused by insufficient ventilation of equipment Damage caused by failure to comply with applicable safety standards or regulations Damage caused by natural disasters or force majeu...

Page 20: ...harmonic distortion Single Phase THD 3 Linear load 1 5 3 Stages equalization Optional Self adaption to BMS 4680W 6500W 11A 11A 2 1 1 370V 100V 500V 125 425V 125V 3600W 5000W 3960W 5500W 21 7A 15 7A Ma...

Page 21: ...1 SOLARMAN Business App Configuration FOR INSTALLERS...

Page 22: ...oid SOLARMAN Smart 2 Download the SOLARMAN Business app As the installer or business owner download the SOLARMAN Business app onto a smartphone or tablet Create an account if you do not already have o...

Page 23: ...device and selecting the network beginning AP from the list Once you have selected the AP network you will be asked for the network password The password can be found on the dongle or on the box sign...

Page 24: ...ype the following credentials Username admin Password admin You will then be taken to an index page titled Inverter information From this page select Wizard in the menu Select your preferred network L...

Page 25: ...5 Select the next button and input your local network password On page 2 3 select Next Once in page four finalise the network configuration by selecting OK...

Page 26: ...e relevant detail regarding the customer s system For the purpose of this manual we only enter Plant Name and Installed Capacity but you should enter all the information you can If your system include...

Page 27: ...7...

Page 28: ...n move forward to selecting the Authorise User icon 9 Authorise Customer as User Select Authorise User and click the add user icon in the top right hand corner of the screen A pop up menu should then...

Page 29: ...has logged in to SOLARMAN Smart and the plant is visible they can press the three dots on the top right of the home page select Plant Info and they can upload a picture of their PV array to have as th...