background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATOR MANUAL 

 
 
 
 
 

OSD2153 SERIES 

GIGABIT ETHERNET 

MEDIA CONVERTER 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for OSD2153 Series

Page 1: ...OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER ...

Page 2: ......

Page 3: ... 2 1 WARNING AND PRECAUTIONS 9 2 2 2 OSD2153 DRAWINGS AND DIMENSIONS 10 2 2 3 POWER SUPPLY CONNECTIONS 11 2 2 4 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS 11 2 2 5 LED INDICATORS 12 2 2 6 CONTROLS 13 2 2 7 FITTING SFP CONNECTORS 14 2 2 8 BASIC CONNECTIONS 14 2 3 OSD2153 OPERATION 15 2 3 1 SINGLE UNIT CONFIGURATION 15 3 MAINTENANCE 18 3 1 INTRODUCTION 18 3 2 EXTERNAL INSPECTION 18 3 3 ROUTINE MAINTENAN...

Page 4: ...3 FIGURE 8 FITTING REMOVING SFP CONNECTORS 14 FIGURE 9 BASIC CONNECTIONS 14 FIGURE 10 LINK LOSS FORWARDING FUNCTION 15 FIGURE 11 SINGLE UNIT CONFIGURATION 15 FIGURE 12 COPPER CONNECTION LOSS 17 FIGURE 13 FIBER CONNECTION LOSS 17 FIGURE 12 COPPER CONNECTION LOSS 17 FIGURE 13 FIBER CONNECTION LOSS 17 TABLE 1 TECHNICAL SPECIFICATIONS 7 TABLE 2 MODULE POWER CONNECTION 11 TABLE 3 LED FUNCTION 12 TABLE ...

Page 5: ... OSD2153 module is intended for isolated use and requires an external power source 1 1 2 APPLICATIONS Any network utilising a mix of copper and fiber Extremely space constrained environments Industrial IP communications Gigabit Ethernet backbone networks 1 1 3 FEATURES AND BENEFITS Complies with IEEE802 3i 802 3u 802 3ab 10 100 1000Base T IEEE802 3z 1000Base Lx Sx standards Supports network traffi...

Page 6: ...OPTICAL SYSTEMS DESIGN DOC ID 10115703 OSD2153 OPERATOR MANUAL PAGE 6 1 2 TYPICAL CONFIGURATION Figure 1 below indicates the typical set up for an OSD2153 system FIGURE 1 OSD2153 TYPICAL CONFIGURATIONS ...

Page 7: ...al Data Rate 100Mbps or 1000Mbps Operating Mode Half or full duplex for 10 100 Full duplex for 1000 Flow control Electrical Data Connector RJ45 Optical connector SFP SFP Options Short haul long haul single fiber operation etc Please consult OSD datasheet 10210000X or contact OSD Controls 1 100 or 1000Mbps on fiber 2 Link Loss Forwarding On Off 3 Fault Detection fiber port or copper and fiber Dimen...

Page 8: ...ng the user choice to use either one or two fiber communications with various optical power outputs depending on the distance required Also on the front panel is a 2 way term block power connector and on the rear panel is a 3 Way DIP switch Each section will be described further throughout this manual OSD2153 Front Panel OSD2153 Rear Panel FIGURE 2 OSD2153 CONNECTORS SFP port Fixed RJ45 Copper Por...

Page 9: ...ct may cause radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 20011 standard Class 1 The OSD2153 is a Class 1 laser product PRECAUTIONS All service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures dur...

Page 10: ...03 OSD2153 OPERATOR MANUAL PAGE 10 2 2 2 OSD2153 DRAWINGS AND DIMENSIONS The OSD2153 is designed to be mounted on an even surface and to be secured by means of M4 or smaller screws FIGURE 3 OSD2153 DIMENSIONS 51 3 49 3 8 6 21 3 Ø3 2 51 3 ...

Page 11: ...anel as indicated in Table 2 TABLE 2 MODULE POWER CONNECTION External Power Pin Specification Pin 1 8 to 35VDC Pin 2 Ground 0V FIGURE 4 MODULE POWER SUPPLY CONNECTIONS 2 2 4 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS Figure 5 shows the pin configuration for the fixed RJ45 copper port FIGURE 5 FIXED RJ45 ETHERNET CONNECTORS 1 Tx 2 Tx 3 Rx 4 Not Used 5 Not Used 6 Rx 7 Not Used 8 Not Used Green LED Fdx A...

Page 12: ...linking Fiber Speed 100Mbps Fiber Speed 1Gbps Copper Link Amber 10Mbps Bi colour 100Mbps Green 1Gbps No Copper Link Activity 1 Full Duplex on Copper Port Half Duplex on Copper Port Power On Power Off Fiber Link No Fiber Link Activity 1 Link Loss Forwarding Enabled Link Loss Forwarding Disabled Note 1 Activity indicates traffic for both copper and fiber port ...

Page 13: ...ed switch settings before powering the unit FIGURE 7 OSD2153 3 WAY DIP SWITCH TABLE 4 OSD2153 3 WAY DIP SWITCH SETTINGS SWITCH NUMBER DESCRIPTION SWITCH POSITION FUNCTION 1 Optical Port Speed OFF 1000BASE X ON 100BASE X 2 Link Loss Forwarding OFF Disable ON Enable 3 Fault Detection OFF Detect LLF for copper and fiber loss ON Detect LLF for fiber loss only ON Position OFF Position 1 2 3 Fiber Speed...

Page 14: ...ion Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until it locks into place Remove plastic rubber dust cap and fit appropriate fiber cable Removing SFP Remove fiber connector Pull the SFP lever down to unlock SFP from housing Using the lever gently pull the SFP out Fiber SFP FIGURE 8 FITTING REMOVING SFP CONNECTORS 2 2 8 ...

Page 15: ...nit Configuration and Dual Unit configuration Figure 10 is a flow chart of the OSD2153 Link Loss Forwarding LLF function and operation FIGURE 10 LINK LOSS FORWARDING FUNCTION 2 3 1 SINGLE UNIT CONFIGURATION The single unit configuration enables the user to connect the OSD2153 to any 1000Base X switch via the fiber port The fixed RJ45 copper port can be connected to a switch or PC using standard CA...

Page 16: ...onse Action Disable Tx of copper port Disable Tx of copper port Restore Sequence 1 Fix fault and reconnect 2 Wait for link to be reestablished 1 Fix fault and reconnect 2 Wait for link to be reestablished Copper link loss Response Action Disable Tx of fiber port NULL Restore Sequence 1 Fix fault and reconnect 2 Wait for link to be reestablished NULL TABLE 6 CONFIGURATION WITH LLF DISABLED Configur...

Page 17: ...00Base X switch will thus be notified that there has been a copper link loss FIGURE 12 COPPER CONNECTION LOSS Figure 13 is an example of a fiber connection loss If the OSD2153 does not receive a valid optical signal from the switch transmission to copper port will be disabled FIGURE 13 FIBER CONNECTION LOSS OSD2153 1000Base X Switch Switch or PC Fiber Copper Tx Rx Tx Tx Tx Rx Rx Rx OSD2153 1000Bas...

Page 18: ...be damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION Visually check for the following Check that the correct power source is connected to the power socket Check that the Ethernet cables are connected ...

Page 19: ...ive for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the right to repair or replace any faulty goods Freight costs and insurance for both journeys are met by the user All equipment repaired by OSD will have a 3 Month Warranty from the date of dispatch 4 2 ...

Page 20: ...Vuko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N 83 003 020 504 Printed in Australia ...

Reviews: