UPS Management
Syntax
[RW_UPS_SECTION]
CFG_USE_UPS_MNG = <TRUE | FALSE>
CFG_NUM_OF_UPSES = <Number of UPSs>
CFG_NUM_OF_POWERSUPPLIES = <Number of PSUs>
CFG_MIN_NUM_OF_UPSES = <Minimum number of UPSs>
CFG_UPS_INPUT_LOST_DELAY = <Input Lost Delay>
CFG_UPS_COMMUNICATION_LOST_DELAY = <Communication Lost Delay>
CFG_UPS_ONLINE_DELAY = <Online Delay>
CFG_UPS_TIMED_SLEEP_PERIOD = <Sleep period>
CFG_UPS_GET_COMMUNITY_NAME = "<Get-request Community Name>"
CFG_UPS_SET_COMMUNITY_NAME = "<Set-request Community Name>"
CFG_UPS1_SERIAL_NUMBER = <UPS1 Serial number>
CFG_UPS1_CAPACITY = <UPS1 Capacity>
CFG_UPS2_SERIAL_NUMBER = <UPS2 Serial number>
CFG_UPS2_CAPACITY = <UPS2 Capacity>
CFG_UPS3_SERIAL_NUMBER = <UPS3 Serial number>
CFG_UPS3_CAPACITY = <UPS3 Capacity>
CFG_UPS4_SERIAL_NUMBER = <UPS4 Serial number>
CFG_UPS4_CAPACITY = <UPS4 Capacity>
CFG_UPS_USE_STATIC_IP = <TRUE | FALSE>
CFG_UPS_STATIC_IP1 = <UPS1 IP Address>
CFG_UPS_STATIC_IP2 = <UPS2 IP Address>
CFG_UPS_STATIC_IP3 = <UPS3 IP Address>
CFG_UPS_STATIC_IP4 = <UPS4 IP Address>
CFG_UPS_SVB_BOOT = <TRUE | FALSE>
CFG_UPS_SHUTOFF_DELAY = <Shutoff Delay>
CFG_AUTO_DETECT = <TRUE | FALSE>
Description
CFG_USE_UPS_MNG
Specify whether the UPS management by the EM card is enabled or not.
1: TRUE (enable)
0: FALSE (disable)
The default setting is "0" (disable).
CFG_NUM_OF_UPSES
Specify the number of UPSs managed by the EM card. The default setting is "0."
CFG_NUM_OF_POWERSUPPLIES
Specify the number of power supply units (PSUs) installed in the Blade Enclosure.
The default setting is "1."