147
-
Managed Power
Indicates the power consumption of all components in the Blade Enclosure managed by the EM
card.
Maximum Power Consumption
Indicates the maximum power consumption allowable for the system. The value is calculated based
on the maximum input power described in the previous item taking the power efficiency into
account.
Allocated Power
Indicates the power already allocated to all components in the Blade Enclosure.
Power Redundancy Status
Indicates the power redundancy status of the relevant Blade Enclosure.
Indications are as follows.
Redundant (lit green):
Power redundancy is maintained.
Redundancy decreased (lit amber): Power redundancy is maintained. But, failed power supply unit
is included.
No redundancy (lit amber):
Redundancy is lost.
Lack of power source (lit red):
Shortage of power source occurs.
Unknown (off):
Redundancy status is unknown.