- 80 -
Built-in UPS Unit
Syntax
[RW_BIUPS_SECTION]
CFG_USE_BIUPS_MNG = TRUE | FALSE
CFG_BIUPS_SVB_SHUTDOWN = TRUE | FALSE
CFG_BIUPS_INPUT_LOST_DELAY = <Delay time>
CFG_BIUPS_SVB_BOOT = TRUE | FALSE
CFG_BIUPS_START_DISCHARGE_ONLY_SVB_DCON = TRUE | FALSE
Description
CFG_USE_BIUPS_MNG
Specify whether to use the built-in UPS unit.
1: TRUE (enable: Use the built-in UPS unit.)
0: FALSE (disable: Does not use the built-in UPS unit.)
The default setting is "0" (disable).
If this parameter is set to "1" (enable), specify "2" (N+1 redundant mode) for
"CFG_PSU_MODE", and "0" (disable) for "CFG_USE_UPS_MNG".
CFG_BIUPS_SVB_SHUTDOWN
Specify whether to shutdown CPU blades when the power required for system operation
cannot be secured due to power failure.
1: TRUE (enable: Shuts down the CPU blade.)
0: FALSE (disable: Does not shut down the CPU blade.)
The default setting is "0" (disable).
CFG_BIUPS_INPUT_LOST_DELAY
Specify the time to start shutdown of CPU blades (in second) when the power required for
system operation cannot be secured due to power failure.
If the power failure is recovered within the time specified in this parameter, the shutdown
of the CPU blade will not start.
The default setting is "20" seconds.
CFG_BIUPS_SVB_BOOT
Specify whether to boot CPU blades when the power failure is recovered and all the CPU
blades in shutdown state become ready.
1: TRUE (enable: Boots the CPU blade.)
0: FALSE (disable: Does not boot the CPU blade.)
The default setting is "0".