65
-
Enabling access from NEC Dianascope and NEC ESMPRO Manager
Ver.5 or later
Syntax
[RW_DSG_SECTION]
CFG_DSG_PASSWORD = <password>
CFG_DSG_ENABLED = <TRUE | FALSE>
CFG_DSG_IP1 = <IP Address1>
CFG_DSG_PORT1 = <port1>
CFG_DSG_IP2 = <IP Address2>
CFG_DSG_PORT2 = <port2>
Description
CFG_DSG_PASSWORD
Stores the user password for linking with NEC DianaScope and NEC ESMPRO Manager
Ver.5 or later. See the Notes below.
CFG_DSG_ENABLED
Specifies whether to enable or disable linkage with NEC DianaScope and NEC ESMPRO
Manager Ver.5 or later. The default value is "1" (enable).
1:TRUE (enable)
0:FALSE (disable)
CFG_DSG_IP1
Specifies the IP address of primary destination for configuration change notification. The
default value is "0.0.0.0".
CFG_DSG_PORT1
Specifies the port number of primary destination for configuration change notification.
The default value is "0".
CFG_DSG_IP2
Specifies the IP address of secondary destination for configuration change notification.
The default value is "0.0.0.0".
CFG_DSG_PORT2
Specifies the port number of secondary destination for configuration change notification.
The default value is "0".