- 26 -
Connection via Serial Port
Connect a management console (e.g., personal computer) to the serial port. When you use the EM
card for the first time, the management console must be connected.
The management console such as PC must have a communication software conformed to VT-100.
Set the communication software as follows:
–
Baud rate: 115200bps
–
Data length: 8 bits
–
Parity: None
–
Stop bit: 1
–
Flow control: None
IMPORTANT:
A leased line cannot be connected to the serial port
directly.
Connection via Network Port
TELNET or SSH (password authentication) is used for connection with network. To login the EM
card with TELNET/SSH, use the IP address you have assigned previously in the procedure for
connection via the serial port.
NOTE:
The default IP address is 192.168.1.8/24. You may connect
with the local network that accepts this IP address to set an IP address.
Note that, however, connection with network is aborted when you
change an IP address. The SIGMABLADE monitor described in
Section 5 also allows you to set an IP address.
IMPORTANT:
To connect with the management network, use "EM1
port" and "EM2 port" connectors at the rear of the Blade Enclosure.