-
61
-
CFG_DHCP_SWM_SLOT1_IP (n: 1 to 6)
Specify the IP address of the switch module installed in switch module slot #n.
This item can be edited when CFG_DHCP_ENABLE_SLOT_IP is "1" (enable).
Specify "0.0.0.0" for the slot which is not enabled.
CFG_DHCP_UPS1_IP (n: 1 to 4)
Specify the IP address of UPS #n.
This item can be edited when CFG_DHCP_ENABLE_SLOT_IP is "1" (enable).
Specify "0.0.0.0" for the slot which is not enabled.
CFG_NAS_OFF_TIMEOUT_RATIO
<NAS blade off time>: Timeout period until the power-off request for NAS blade is
executed.
It shall be specified by a percentage of CFG_SVB_SHUTDOWN_TIMEOUT value.
The default is 50%. Since the default value of CFG_SVB_SHUTDOWN_TIMEOUT is
300 seconds, the timeout period is 150 seconds.
CFG_CPU_ON_TIMEOUT_RATIO
<CPU blade on time>: Timeout period until the power-on command for linking CPU
blade is executed.
It shall be specified by a percentage of CFG_RACKPOW_RESPONSE_TIMEOUT value.
The default is 50%. Since the default value of
CFG_RACKPOW_RESPONSE_TIMEOUT is 300 seconds, the timeout period is 150
seconds.
Notes
Make sure that the IP addresses distributed through DHCP server of EM card do not overlap with
the IP addresses of other devices.
When specifying consecutive IP addresses in CFG_DHCP_BASE_IP, make sure that "base address
+ 13" (or "base a 17" when using the UPS management feature is used) is smaller than 254.
When CFG_DHCP_ENABLE_SLOT_IP is enabled (the IP addresses are assigned to every slot), the
IP address must be in the same segment as that in EM card.
Maximum power consumption management is not available when using automatic CPU blade boot
after UPS power recovery.
The [4+0] status in the power supply system configured with four power supply units is not
supported when the system is in "N+1 redundant mode" and "CPU performance mode".
Summary of Contents for N8405-019
Page 4: ... ii ...
Page 6: ... iv ...
Page 8: ... vi ...
Page 10: ... viii ...
Page 12: ... x ...
Page 20: ......
Page 231: ... 211 N8403 099 F N8403 100 F ...
Page 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...