53
-
CPU Blade
Syntax
[RW_SVB_SECTION]
CFG_SVB1_DELAY_TIME = <Boot delay time 1>
CFG_SVB2_DELAY_TIME = <Boot delay time 2>
CFG_SVB3_DELAY_TIME = <Boot delay time 3>
CFG_SVB4_DELAY_TIME = <Boot delay time 4>
CFG_SVB5_DELAY_TIME = <Boot delay time 5>
CFG_SVB6_DELAY_TIME = <Boot delay time 6>
CFG_SVB7_DELAY_TIME = <Boot delay time 7>
CFG_SVB8_DELAY_TIME = <Boot delay time 8>
Description
CFG_SVBn_DELAY_TIME (n: numeric between 1 and 8 which corresponds to slot
number)
This command is used to specify the delay time for issuing power-on permission to each
CPU blade. Specify the delay time in seconds.
The default setting is "0" (no delay).
NOTES:
This feature is used to boot the CPU blade after the peripheral
devices has started up when automatic power management by AC
linkage feature is enabled.
If you want to fix the boot order at start-up of the CPU blade (AC
power is turned on) using this feature, check the time duration until
the CPU blade is powered on when this feature is disabled. Then,
specify the similar time in seconds.
IMPORTANT:
The POWER switch does not power on the CPU blade
during delay time. Wait until the delay time is over.