- 56 -
CFG_LAN_DOWN_SWITCHOVER
When using the EM card in redundant configuration, specify whether to treat the link
down of management LAN detected by the active EM card as switchover factor of EM
card.
1: TRUE (Switchover)
0: FALSE (Does not switchover)
The default setting is "0" (does not switchover).
CFG_LAN_DOWN_WAIT
If the link down of management LAN is treated as switchover factor of EM card, specify
the time until the EM card judges it as link down. (Unit: second)
The default setting is 5 seconds. If the link down period is within the specified time, the
switchover is suppressed. Use the default value in usual operation.
CFG_LAN_BRIDGE
Specify whether to enable or disable the bridge feature of EM card for the management
LAN. The default setting is "1" (enable). Use the default setting in usual operation.
1: TRUE (enable)
0: FALSE (disable)
Notes
If you are using EM firmware revision 04.xx or earlier and intend to transfer the EM syslog to an
external syslog server, be sure to start the syslog server before starting the EM. If the syslog server
is not started when the EM attempts to write syslog to the syslog server, the syslogd command is
aborted and no syslog is collected. This restriction is not applied to EM firmware revision 05.xx or
later.
If the bridge feature of the EM card is disabled, an access to EXPRESSSCOPE Engine or the
management LAN port on the switch module is denied.