Basic Setup in Configuration File
This section describes the basic setup in configuration file.
Overview
Various settings for EM card are saved in a dedicated configuration file (in text format).
File name: /var/nvdata/rw_poem.conf
To edit the configuration file, use Edit Configuration menu in Web console. (See Chapter 4, "Using
Web Console Feature" for details.) Or, you may use "vi" command.
NOTE:
A file that is created or edited on the other computer can be
transferred via ftp. In this case, use a character code "EUC", and line
feed code "LF" in the file.
The following format is commonly used in configuration file.
-----------------------------------------------------------------
[<section-name>]
<item-name> = <set-value>
-----------------------------------------------------------------
When a character string is used for <set-value>, the character string must be enclosed with double
quotation marks.
NOTE:
A line containing space characters only is ignored.
IP Address of EM Card
The two EM cards installed in Blade Enclosure use the four IP addresses in total. These addresses
are classified into two types; "Static IP" is determined by the slot to install the EM card, and
"Floating IP" is used by the active EM card regardless of the installation slot.
The last bit of "Static IP" corresponds to the installation slot.
The last bit of "Floating IP" is defined as "0" for active EM card and "1" for standby EM card.